TROUBLESHOOTING GUIDE
1921 | 208 VAC | 60 HZ. | 3 PHASE |
1922 | 240 VAC | 60 HZ. | 3 PHASE |
|
|
|
|
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
|
Oven fan will not run | Incoming power supply | Check circuit breakers. Reset if required. Call power | |
|
| co. if needed. |
|
| Fuses, 10 Amp, motor and | Check, replace if necessary. | |
| controls |
|
|
| Fuse holder | Check, replace if necessary. | |
|
|
| |
| Terminals are normally closed. If open, reset | ||
| Oven cavity | thermostat and retest. If thermostat will not hold for | |
|
| maximum oven temperature, and oven is not exceeding | |
|
| temperature setting, check for proper location of | |
|
| capillary bulb in its spring holder. If the capillary checks | |
|
| okay, replace the | |
| Switch, main power | Check continuity between switch terminals. Replace | |
|
| switch as needed. |
|
| 30 minute time delay relay | Check for supply voltage to 30 minute time delay relay | |
|
| at terminals #1 and #6. If no voltage is present, trace | |
|
| wiring back to main power switch. If there is supply | |
|
| voltage at terminals #1 and #6, check for output voltage | |
|
| at terminals #2 and #3. If there is incoming voltage but | |
|
| no output voltage, and the main power switch is on, | |
|
| replace the 30 minute time delay relay. | |
| Relay, main fan | Check for supply voltage to relay contacts, if no voltage | |
|
| is present, trace wiring back to power supply. Check for | |
|
| supply voltage to the coil of the main fan relay. If no | |
|
| voltage is present, trace wiring back to the 30 minute | |
|
| time delay relay. If voltage is present, check to insure | |
|
| contacts are closing. Replace as needed. | |
| Transformer, Motor | Check for 240 VAC supply to the transformer primary. If | |
| (MODEL 1922 ONLY) | no voltage is present, trace wiring back to relay. If | |
|
| 240VAC is present at transformer primary, check for | |
|
| 208VAC at the transformer secondary. If there is | |
|
| primary voltage, but no secondary voltage, replace | |
|
| transformer. |
|
| Circuit breaker(s), 3A. | Push and reset circuit breakers. Check for voltage to | |
|
| the circuit breaker. If no voltage is present, trace wiring | |
|
| back to the main fan relay. If there is voltage present, | |
|
| proceed. Check for continuity through the circuit | |
|
| breaker, if the circuit breaker has been reset and there | |
|
| is no continuity through the circuit breaker, replace the | |
|
| circuit breaker. |
|
| Main fan motor | Check for supply voltage at motor. If no voltage is | |
|
| present, trace wiring back to circuit breakers. | |
|
| WITH POWER OFF: Check for opens, shorts or | |
|
| grounds. Turn fan blade to check for locked rotor. | |
| Capacitor | Check for shorts or grounds. | |
|
| WARNING: Capacitor has a stored charge, discharge | |
|
| before testing. |
|
Oven will not heat | Main fan motor | Check for main fan operation. If it is not operating, refer | |
|
| to “Oven fan will not run”. | |
| Air pressure switch | This normally open switch should close when the main | |
|
| fan is activated. Refer to the “Removal and installation” | |
|
| section for proper adjustment. Replace as needed. |
6 | DTF – 1920 Series Service Manual |