TROUBLESHOOTING GUIDE

1921

208 VAC

60 HZ.

3 PHASE

1922

240 VAC

60 HZ.

3 PHASE

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

EVALUATION

 

Oven fan will not run

Incoming power supply

Check circuit breakers. Reset if required. Call power

 

 

co. if needed.

 

 

Fuses, 10 Amp, motor and

Check, replace if necessary.

 

controls

 

 

 

Fuse holder

Check, replace if necessary.

 

 

 

 

Hi-limit thermostat,

Terminals are normally closed. If open, reset

 

Oven cavity

thermostat and retest. If thermostat will not hold for

 

 

maximum oven temperature, and oven is not exceeding

 

 

temperature setting, check for proper location of

 

 

capillary bulb in its spring holder. If the capillary checks

 

 

okay, replace the hi-limit thermostat.

 

Switch, main power

Check continuity between switch terminals. Replace

 

 

switch as needed.

 

 

30 minute time delay relay

Check for supply voltage to 30 minute time delay relay

 

 

at terminals #1 and #6. If no voltage is present, trace

 

 

wiring back to main power switch. If there is supply

 

 

voltage at terminals #1 and #6, check for output voltage

 

 

at terminals #2 and #3. If there is incoming voltage but

 

 

no output voltage, and the main power switch is on,

 

 

replace the 30 minute time delay relay.

 

Relay, main fan

Check for supply voltage to relay contacts, if no voltage

 

 

is present, trace wiring back to power supply. Check for

 

 

supply voltage to the coil of the main fan relay. If no

 

 

voltage is present, trace wiring back to the 30 minute

 

 

time delay relay. If voltage is present, check to insure

 

 

contacts are closing. Replace as needed.

 

Transformer, Motor

Check for 240 VAC supply to the transformer primary. If

 

(MODEL 1922 ONLY)

no voltage is present, trace wiring back to relay. If

 

 

240VAC is present at transformer primary, check for

 

 

208VAC at the transformer secondary. If there is

 

 

primary voltage, but no secondary voltage, replace

 

 

transformer.

 

 

Circuit breaker(s), 3A.

Push and reset circuit breakers. Check for voltage to

 

 

the circuit breaker. If no voltage is present, trace wiring

 

 

back to the main fan relay. If there is voltage present,

 

 

proceed. Check for continuity through the circuit

 

 

breaker, if the circuit breaker has been reset and there

 

 

is no continuity through the circuit breaker, replace the

 

 

circuit breaker.

 

 

Main fan motor

Check for supply voltage at motor. If no voltage is

 

 

present, trace wiring back to circuit breakers.

 

 

WITH POWER OFF: Check for opens, shorts or

 

 

grounds. Turn fan blade to check for locked rotor.

 

Capacitor

Check for shorts or grounds.

 

 

WARNING: Capacitor has a stored charge, discharge

 

 

before testing.

 

Oven will not heat

Main fan motor

Check for main fan operation. If it is not operating, refer

 

 

to “Oven fan will not run”.

 

Air pressure switch

This normally open switch should close when the main

 

 

fan is activated. Refer to the “Removal and installation”

 

 

section for proper adjustment. Replace as needed.

6

DTF – 1920 Series Service Manual

Page 6