A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - RANGER 10,000 PLUS (K1419-5 ), (K2468-2) RANGER 10,000 (K2160-4)

INPUT - GASOLINE ENGINE

Make/Model

(K1419-5)

Kohler

CH23S

(K2468-2)

Subaru Robin

EH65

(K2160-4)

Honda

GX620KI

Description

2cylinder 4 Cycle

Air-Cooled

Gasoline

Engine.

Aluminum Alloy

with Cast Iron

Liners,

Electronic

Ignition

Horsepower

23 HP @

3600 RPM

Kohler

22HP@ 3600 RPM

SUBARU ROBIN

20HP@ 3600 RPM

Honda

Operating

Speed (RPM)

High Idle 3700

Full Load 3500

Low Idle 2200

Displacement

cu. in.

(cu.cm.)

41(674)

Kohler

39.9(653)

SUBARU ROBIN

37.5(614)

Honda

Starting

 

Capacities

System

 

 

 

 

Fuel:

 

 

9 Gal (34 L)

12VDC

 

Lubricating Oil:

Battery

 

2.0 Qts. (1.9 L)

Electric Start

 

 

 

Group 58

 

Fuel:

Battery

 

(435 cold

 

9 Gal (34 L)

Cranking

 

Lubricating Oil

Amps)

 

1.6 Qts. (1.6L)

 

 

 

 

 

Fuel:

 

 

9 Gal (34 L)

 

 

Lubricating Oil

 

 

1.9 Qts. (1.8L)

 

 

 

 

 

 

RATED OUTPUT @ 104°F (40°C)- WELDER

Welding Output

AC Constant Current 225A / 25V / 100%

DC Constant Current 210A / 25V / 100%

DC Constant Voltage 200A / 20V / 100%

RATED OUTPUT @ 104°F (40°C)- GENERATOR

Auxiliary Power 1

RANGER 10,000 PLUS

9,000 Watts Continuous, 60 Hz AC

10,500 Watts Peak, 60 Hz AC

120/240 Volts

RANGER 10,000

9,000 Watts Continuous, 60 Hz AC

10,000 Watts Peak, 60 Hz AC

120/240 Volts

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

30.3 in.

19.1 in.

42.0 in.

502 lbs. (228kg) K1419-5

770 mm

485 mm

1067 mm

528 lbs. (240kg) K2468-2

 

 

 

505 lbs. (229kg) K2160-4

 

 

 

 

1.Output rating in watts is equivalent to volt - amperes at unity factor.Output voltage is within +/-10% at all loads up to rated capacity. When welding available auxiliary power will be reduced.

RANGER 10,000 PLUS AND RANGER 10,000 & RANGER 10,000

Page 8
Image 8
Lincoln Electric 11395, 10,000 PLUS manual Installation, Height Width Depth Weight