Lincoln Electric 450 CE Product Description, Protective, Ground, Duty Cycle, Design Features

Models: 450 CE

1 32
Download 32 pages 8.48 Kb
Page 15
Image 15

b-2

OPERATION

b-2

 

 

 

GRAPHIC SYMbOLS THAT APPEAR ON THIS MACHINE OR IN THIS MANUAL

UOPEN CIRCUIT

0 VOLTAGE

U1

INPUT VOLTAGE

U2

OUTPUT VOLTAGE

I1

INPUT CURRENT

I2

OUTPUT CURRENT

 

PROTECTIVE

 

GROUND

PRODUCT DESCRIPTION

The FLEXTEC™ 450 CE is a multi-process CC/CV DC inverter and is rated for 450 amps, 38 volts at a 60% duty cycle. The Flextec is intended for both fac- tory and field operation. It comes in a compact, rugged case that is designed for portability and out- door use with an IP23 environmental rating. The user interface of the FLEXTEC™ 450 CE is simple and intuitive. Weld modes are selected by a 4 position selector switch. Volts and Amps are displayed on an easy to view LED display, and the amps and volts are set by a large output control knob. A hot start toggle selector switch and an arc control knob allow for finer tuning of the welding arc. The FLEXTEC™ 450 CE operates on 380V, 400V, or 415V 50hz or 60hz power.

DUTY CYCLE

The FLEXTEC™ 450 CE is capable of welding at a 100% duty cycle (continuous welding) at 400 amps rated output. The 60% rating is 450 amps base off of a 10 minute cycle - 6 minutes on time and 4 minutes off time. The maximum output of the machine is 500 amps.

The FLEXTEC™ 450 CE is also rated for Desert Duty, elevated temperature operation, in a 55°C(131°F) ambient. The machine is output de-rated for this application.

WARNING or CAUTION

Explosion

Dangerous Voltage

Shock Hazard

DESIGN FEATURES

Severe Duty Design for outdoor use (IP23 rating).

Passive Power Factor Correction – reliably gives 95% power factor for lower installation costs.

89% Efficiency rating – reduces electrical utility costs.

Simple user interface - designed with the operator in mind. Getting setup for the weld is several clicks away and even the most novice welder can be confi- dent he is setup properly.

F.A.N. (fan as needed). Cooling fan runs when the output is energized and for a 5 minute cool down period after output is disabled.

Thermal protection by thermostats with Thermal Indicator LED.

Error Codes display on LED screen for ease of trou- ble shooting.

Electronic over current protection.

Input voltage misconnection protection.

Utilizes digital signal processing and microprocessor control.

VRD™ Voltage Reduction Device - Enable this func- tion for reduced OCV in CC modes for added safety.

FLEXTEC™ 450 CE

Page 15
Image 15
Lincoln Electric 450 CE manual Product Description, Protective, Ground, Duty Cycle, Design Features