A CLOSER LOOK
Tandem MIG 800 Amp Welding Torch
Torch Specifications :
Duty Cycle: 800 amps 60% duty, mixed gas 700 amps 100% duty, mixed gas
Max. current per electrode: 450 amps
Cooling requirements: one water circulating source providing a min. of .45 gpm, at 40 psi
Weight: 7.5 lbs. (with cables elevated 1 ft., 4 ft. from torch mounting bracket)
Available Lengths: 4 ft., 6 ft., 8 ft., 10 ft., 12 ft.
Compatible Torch Reamer with external sprayer:
Torch mounting to Power Feed 10 Robotic wire feeders
The 800 amp Tandem MIG torch is supplied with Power Feed 10 Robotic Wire Feeder compatible cable ends. The cable assemblies plug directly into the feeder power block, (with
Torch Dimensions
Torch mounting bracket is included as part of the torch assembly (dimensions in inches [millimeters])
Torch alignment fixture L10430-1
Torch alignment should be performed after any severe torch collision or after any major torch disassembly. The
|
| ORDERING INFORMATION: |
|
| |
|
| Welding torch with torch mounting bracket and diffusers (less contact tips and liners) |
| ||
|
| Description | Part number | Shipping weight |
|
|
| Torch with 4 ft. cables | 18.4 lbs. |
| |
|
| Torch with 6 ft. cables | 21.8 lbs. |
| |
|
| Torch with 8 ft. cables | 25.2 lbs. |
| |
Torch alignment fixture |
| Torch with 10 ft. cables | 28.6 lbs. |
| |
|
| Torch with 12 ft. cables | 32.0 lbs. |
| |
|
|
|
|
|
|
EXPENDABLE REPLACEMENT PARTS
Water-Cooled Nozzle
Standard on all 800 amp torches.
The
assembly is designed to provide maximum
gas coverage for both high speed and high deposit applications. Nozzle features brass construction for maximum rigidity and cooling.
Nozzle Retainers
Two different nozzle retainers are
available for different electrode spacing.
Nozzle retainers are available with two different contact tip spacings — standard and wide. Each retainer provides the mounting surface for the gas nozzle and establishes contact tip spacing. An air blast hose is part of each assembly.
S22693-152 (Std.)
S22693-135 (Wide)
Nozzle Retainer Insulators
Two different Nozzle Retainer Insulators are available to accommodate different electrode spacing.
Torch Nozzle Retainer Insulator mounts
between the torch retainer and gas diffusers, protecting the retainer and providing orifices for air blast cleaning. There are two different sized insulators to fit the two retainer sizes.
Tandem MIG 800 Amp Welding Torch