Lincoln Electric manual Technical Specifications DC-400

Models: DC-400

1 42
Download 42 pages 48.7 Kb
Page 8
Image 8

A-1

INSTALLATION

 

A-1

TECHNICAL SPECIFICATIONS – DC-400

 

 

 

 

INPUT-THREE PHASE ONLY

 

 

Standard

Input Current at Rated Output (CVI)

Voltage

 

 

 

 

Frequency

100% Duty Cycle

60% Duty Cycle

50% Duty Cycle

 

400Amps/36V

450Amps/38V

 

500Amps/40V

230/460/575V/60Hz

78/39/31Amps

83/41/33Amps

84/42/34Amps

 

400Amps/36V

450Amps/38V

 

500Amps/40V

220/230/380/400/415/440V/50/60Hz 81/77/47/45/43/41Amps

85/81/49/47/45/42Amps

86/82/50/48/46/43Amps

 

RATED OUTPUT

 

 

Duty Cycle (1)

Amps

Volts at Rated Amps

100%

400

36

 

 

60%

450

38

 

 

50%

500

40

 

 

 

OUTPUT

 

 

 

OUTPUT

MAXIMUM OPEN CIRCUIT VOLTAGE

AUXILIARY POWER

Min.----60A 12V CV(22V CC)

57V. (CC) 45.5V. (CVI)

60Hz

115 VAC, 15 AMPS

Max.---500A 42V (CC, CV)

54V. (CC) 45.5V. (CVI) 50/60 Hz

42 VAC, 10 AMPS

RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT.

IN ADDITION, FOLLOW LATEST NATIONAL ELECTRICAL CODE AND LOCAL CODE.

INPUT

INPUT AMPERE

TYPE 75°C

TYPE 75°C

VOLTAGE /

RATING ON

COPPER WIRE IN

GROUND WIRE IN

FREQUENCY

NAMEPLATE

CONDUIT AWG

CONDUIT AWG

 

@100%

(IEC) SIZES (mm2)

(IEC) SIZES (mm2)

 

Duty Cycle

40°C(104°F)

 

230/60Hz

78

3(25)

6(16)

460/60Hz

39

8(10)

10(6)

575/60Hz

31

10(6)

10(6)

BUSSMANN SUPER LAG

 

FUSE SIZE AND

CATALOG NUMBER*

 

 

FUSE SIZE

CATALOG NUMBER

100

 

REN-100

50

 

RES-50

40

 

RES-40

 

 

 

220/50/60Hz 230/50/60Hz 380/50/60Hz 400/50/60Hz 415/50/60Hz 440/50/60Hz

HEIGHT

27.50 in. 699 mm

81

3(25)

8(10)

77

3(25)

8(10)

47

6(16)

10(6)

45

6(16)

10(6)

43

8(10)

10(6)

41

8(10)

10(6)

 

 

 

PHYSICAL DIMENSIONS

WIDTH

DEPTH

22.25 in.

32.0 in.

565 mm

988 mm

100

REN-100

100

REN-100

60

RES-60

60

RES-60

60RES-60

50RES-50

WEIGHT

473lbs.

215kg.

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE -22°F to 104°F(-30°C +40°C)

STORAGE TEMPERATURE RANGE -40°F to 140°F(-40°C+60°C)

(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on an 4 minutes off).

*Use only bussmann Super-Lag fuses specified. Other fuses may not protect the welder and may cause overheating and possible fire damage.

Insulation class 155(F)

IDEALARC® DC-400

Page 8
Image 8