Lincoln Electric IM420-D manual Installation

Models: IM420-D

1 35
Download 35 pages 8.87 Kb
Page 8
Image 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – DC-1000

INPUT - THREE PHASE ONLY

Standard

Voltage

230/460/60

575/60

220/380/440/50/60

380/500/50/60

415/50/60

Input Current at Rated Output

100% Duty Cycle

60% Duty Cycle

50% Duty Cycle

193/96.5

215/108

230/115

77.2

86

92

193/112/96.5

215/124/108

230/133/115

112/85

124/94

133/101

102

113

121

 

 

 

RATED OUTPUT

Duty Cycle

100% Duty Cycle

60% Duty Cycle

50% Duty Cycle

Output Range

150A/16V-1300A/46V

Amps

1000

1140

1250

OUTPUT

Maximum Open Circuit Voltage

75V for 60 HZ models

72V for 50/60 HZ models

Volts at Rated Amperes

44

44

44

Auxiliary Power

See the OPERATION section

for Auxiliary Power

information by model

RECOMMENDED INPUT WIRE AND FUSE SIZES

INPUT

HERTZ

INPUT AMPERE

TYPE 75°C

TYPE 75°C

TYPE 75°C

COPPER WIRE

GROUND WIRE

(SUPER LAG)

VOLTAGE /

 

RATING ON

 

IN CONDUIT

IN CONDUIT

OR BREAKER

FREQUENCY

 

NAMEPLATE

 

AWG(IEC-MM2) SIZES

AWG(IEC-MM2) SIZES

SIZE (AMPS)1

 

 

 

 

 

 

30°C (86°F) Ambient

 

 

 

 

 

 

 

 

230

60

193

000 (85)

4 (21)

300 Amp

460

60

96.5

3 (27)

6 (14)

150 Amp

575

60

77.2

4 (21)

6 (14)

125 Amp

220

50/60

193

000 (85)

4 (21)

300 Amp

380

50/60

112

2 (34)

6 (14)

175 Amp

415

50/60

102

2 (34)

6 (14)

150 Amp

440

50/60

96.5

3 (27)

6 (14)

150 Amp

500

50/60

85

4 (21)

6 (14)

125 Amp

 

 

 

 

 

 

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

30.75 in

22.25 in

39.0 in

821 lbs.

781 mm

567 mm

991 mm

372 kg.

 

 

 

 

1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

IDEALARC® DC-1000

Page 8
Image 8