Lincoln Electric IM648-B specifications Wiring Diagram for Code

Models: IM648-B

1 37
Download 37 pages 56.25 Kb
Page 32
Image 32

WIRING DIAGRAM (FOR CODE 11025)

RIGHT SIDE OF MACHINE

F-3

INPUT

}

PER

N.A.

 

FAN FAN

 

C1

3000/450

-

+

203

206

208

209

205

RELAY 4 1 501

505

207A

H1

 

F

 

C

207

-

C

TP1 TP3

 

E D1

B

B

 

INPUT

 

BRIDGE

TP2

209

D

A

A

 

+

 

A

 

 

 

H1

H2 5

2

H3

 

7

H4

 

8

H5

 

4

H6

 

J22

 

N

8

53

12V

3

56

N

R

2

51

24V

6

54

R

U

9

64

18V

5

62

W

18V

4

61

U

Y

1

FAN

115V

7

FAN

Y

G W

R

B

 

W

V

U

 

 

 

S1

 

A

B

C POWER

 

 

 

S3

S2

 

 

PSI_SET

RESET

 

277A

277B

 

 

223

 

 

 

 

 

 

221

 

FAN

FAN

MOTOR

207A

203

S4 PRIMARY RECONNECT

203

 

207A

202

 

206

 

POWER

204

 

202

207

 

+ C2-

 

3000/450

++VOLT

5

2

502

506

P_XFMR

6

3

503

 

J10

 

507

201

 

 

 

 

 

 

 

 

 

xxxxxxx

404

 

 

 

 

T3

 

I

 

 

 

T1

 

208

 

 

 

CURRENT

 

 

 

 

MAIN

 

204

 

 

 

TRANSFORMER

 

 

 

 

XFMR

Y

I

 

 

 

Y

 

OUT

B

 

 

 

 

 

 

 

-

 

 

 

 

FR

 

-IN

 

 

 

 

S

 

 

 

 

 

 

FR

 

 

 

 

6

 

S

 

 

 

 

 

 

 

S

X2

 

 

2

 

-IN

S

 

 

 

 

FR

 

 

 

3

 

 

 

-OUT

AUXILIARY

J21

 

 

 

 

 

 

 

 

 

 

+15V

TRANSFORMER

 

 

 

 

 

 

 

 

216

15

T2

 

 

 

 

 

 

 

 

RF

217

14

READY LED

 

 

 

 

 

61

62

64

 

TOROID

212

13

LOW_PSI LED

 

 

 

 

 

18V18V

 

 

218

12

POT WIPER

 

 

 

J5

 

1

2

 

 

 

213

11

RESET

 

 

 

 

 

 

 

219

10

GND

 

 

 

 

3

4

 

 

 

 

507

4

8

 

 

 

 

 

P_XFMR

 

 

 

 

 

214

9

THERMAL LED

503

3

7

J1

 

 

 

502 506

2

6

++VOLT

 

 

 

210

8

SAFETY LED

 

 

 

 

 

501 505

1

5

RELAY

 

6

1

 

211

215

7

PSI SET

 

 

 

 

 

 

216

211

6

RESET LED

 

 

 

J4

 

 

7

2

212

275

5

 

 

Y

 

 

 

217

 

 

Y

3

6

CT

 

8

3

218

213

276

4

 

MACHINE

PYTHON

202

MACHINE

206

REAROF

 

SHOWN FOR 400-460VAC OPERATION

N.C.

A

A

0.6A

SLOW BLOW

H2

H3

200-

220-

208V

230V

 

380-

440-

415V

460V

H4 H5

NOTES:

N.A.

X4

 

J33

 

R

 

 

 

 

 

XFER

 

ELEC

3

1

W

 

 

ELEC

XFER

4

2

R

 

 

 

X40

 

W

 

X2

 

 

 

 

 

 

 

X20

 

 

 

B21

 

 

 

 

 

 

 

 

 

 

 

 

 

J37

6

1

360

 

 

 

1 NOZZLE

7

2

 

 

 

 

3,8 WORK

8

3

343 365

 

 

5,10 ELECTRODE

 

 

 

 

9

4

E

 

 

 

 

10

5

 

 

 

J36

5

1

344

 

 

 

G

 

 

 

2,3 = 24V

6

2

54

 

4,8 = OK TO MOVE

7

3

51

 

 

 

 

8

4

347

 

 

 

 

 

 

348

 

 

 

J38

7

1

4

 

 

 

8

2

2

 

 

1,7 TRIGGER

 

 

 

9

3

361

 

 

3,4 AIR SOL

 

 

5,6 ELEC SOL

10

4

366

 

11,12 = 12V

11

5

56

 

 

369

 

 

 

 

12

6

53 364

 

 

 

J39

3

1

4A

 

 

2,4 TRIGGER

4

2

 

 

 

J35

 

 

2A

 

 

 

4

1

309

 

OUTPUT

1 AIR SOL

303

5

2

310

2 ELEC SOL

 

 

3 TRIGGER

6

3

312

 

 

4 IGBT 6 GND

354

 

L1 CHOKE

 

xxxxxxx S

E

 

 

 

401

205

 

 

7

 

 

FR

X20

-OUT

S

 

 

 

 

 

 

 

 

X3

X30

 

201

 

 

 

 

BK

S

 

 

X1

 

 

 

-IN

 

 

 

W

 

 

 

 

 

X10

 

 

 

BK

 

 

 

 

 

 

 

-IN

 

365

NN

 

 

 

-OUT

 

 

 

 

A

S BK

S

360

 

 

 

 

 

BK

 

 

 

 

 

X4

 

X40

 

 

 

 

 

 

 

 

 

 

LEFT SIDE OF MACHINE

OUTPUT BASE CASE FRONT

PC BOARD

PROTECTIVE BONDING CIRCUIT

404

2

5

TSTAT

9

4

219

214

 

 

 

 

223

3

 

401

1

4

10

5

210

215

 

 

 

 

277

2

 

 

 

 

 

J2

 

 

 

 

 

 

221

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3

 

 

 

 

 

 

275

 

 

 

 

J40

W

8

16

 

 

 

 

 

 

 

R1

 

 

 

 

7,8 ELEC SHUNT (TWIST PR)

 

 

 

276

 

 

 

 

 

R

7

15

 

 

 

 

10K

 

 

 

 

 

 

 

 

 

 

277

 

2W

 

 

 

 

306

6

14

 

 

 

 

 

 

 

CONTROL

 

 

 

W

5

13 4,5 XFER SHUNT (TWIST PR)

 

 

 

277A

 

POT

 

 

 

DISPLAY

R

4

12

12 GND

 

 

 

 

 

 

 

CW (MAX)

 

 

 

312

3

11

11 TRIGGER

 

 

 

 

 

 

 

 

 

 

 

 

303

3 IGBT

 

 

 

 

 

 

 

 

 

 

 

 

354

2

10

2,6 PSI SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

302

 

 

 

 

 

 

 

 

 

 

 

 

310

1

9

10 ELEC SOL

 

 

 

 

 

 

 

 

 

 

 

 

309

9 AIR SOL

 

 

 

 

 

344

 

343

348

347

2A

4A

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A B C D E F G H I J K L M N

 

 

 

 

 

 

 

 

 

INTERFACE RECEPTACLE

 

 

 

 

 

 

 

 

 

302

J20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

W

 

 

 

 

 

 

 

 

 

 

 

 

2

Y

 

S5

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

306

1

R

AIR

 

 

 

WORK

 

 

 

 

 

 

 

361

 

 

 

 

W

 

 

 

 

 

 

 

 

 

366

 

 

SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

N

4

2

 

 

 

 

 

 

 

 

 

 

 

7

 

8

 

 

 

 

 

COLOR CODE:

 

 

 

 

9

369

 

 

 

B = BLACK OR GRAY

 

 

 

6

 

 

 

364

 

 

G = GREEN

 

 

 

 

 

 

 

 

 

 

 

 

R = RED OR PINK

 

 

5

 

 

 

 

 

 

 

 

 

W = WHITE

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U = BLUE

 

 

 

4

 

 

1

 

 

 

 

 

N = BROWN

 

 

 

 

 

 

 

 

 

 

Y = YELLOW

 

 

 

3

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT OF

DIAGRAMS

1.FOR MACHINES SUPPLIED WITH INPUT CABLE

FOR SINGLE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK & WHITE LEADS TO SUPPLY CIRCUIT.

WRAP RED LEAD WITH TAPE TO PROVIDE 600V. INSULATION.

FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT.

2.FOR MACHINES NOT SUPPLIED WITH INPUT CABLE

FOR SINGLE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U & W TO SUPPLY CIRCUIT.

FOR THREE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U, V & W TO SUPPLY CIRCUIT.

N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER.

N.C. PLACE "A" LEAD ON APPROPRIATE CONNECTION FOR INPUT VOLTAGE.

 

J40

 

 

 

 

 

 

 

 

 

 

CONNECTION SHOWN IS FOR 440-460V OPERATION.

 

 

 

 

 

 

 

 

 

 

 

1

 

 

15

 

 

 

 

 

 

 

 

N.D. C1 AND C2 CAPACITORS ARE A MATCHED SET.

 

 

 

 

 

 

 

 

 

 

 

 

 

J3

 

J2,J21,J37

J1,J20

J4,J10,

J5,J22,

 

 

J38

 

 

J33,J39

J35

 

J36

 

 

 

1

8

1

5

1

2

1

3

1

4

1

6

 

9

16

6

10

3

4

4

6

5

8

8

12

ELECTRICAL SYMBOLS PER E1537

 

 

 

CONNECTOR CAVITY NUMBERING SEQUENCE

 

 

 

(VIEWED FROM COMPONENT SIDE OF BOARD)

A

L12068

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number..

F-3

Page 32
Image 32
Lincoln Electric IM648-B specifications Wiring Diagram for Code