Lincoln Electric IM648-B Python powers up properly 1. Press Purge button on the front

Models: IM648-B

1 37
Download 37 pages 56.25 Kb
Page 26
Image 26

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The PYTHON powers up properly 1. Press Purge button on the front of

but there is no response when the

the PYTHON. If air does not flow,

trigger is pulled and only the

then:

POWER LED is lit.

a. Auxiliary transformer may be

 

faulty.

 

b. The main gas solenoid assem-

 

bly may be faulty. Check or

 

replace.

 

c. Possible faulty Output Power

 

board.

 

d. Possible faulty Control board.

2. (check for continuity from the bulk- head connector to the molex) See Wiring Diagram.

3. Remove the handles (or barrel) of

the torch and examine all the con-

nections. Pay attention to location If all recommended possible areas of of electrode lead mounting at back misadjustment have been checked of torch head, broken trigger and and the problem persists, Contact

solenoid leads.your local Lincoln Authorized

Field Service Facility.

4.Check for proper trigger switch operation. Remove the torch cable assembly from the PYTHON and test for continuity between 9 and 1 at the quick connect when the trig- ger switch is depressed and no continuity when the switch is not depressed. Replace the trigger switch or torch cable if defective.

5.Possible faulty Control board.

6.Possible faulty Output Power board.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.