Lincoln Electric IM736-D manual Troubleshooting, Problems Possible Areas Symptoms Misadjustments

Models: IM736-D

1 48
Download 48 pages 40.06 Kb
Page 30
Image 30

E-2

TROUBLESHOOTING

E-2

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

 

 

 

 

Major physical or electrical damage

1.

Contact your local authorized

 

is evident when the sheet metal

 

Lincoln Electric Field Service

 

covers are removed.

 

facility for technical assistance.

 

 

 

 

 

Input fuses keep blowing, or input

1.

Make certain that the fuses or

 

breaker keeps tripping

 

breakers are properly sized. See

 

 

 

installation section of the manual

 

 

 

for recommended fuse and

 

 

 

breaker sizes.

 

 

2.

Welding procedure is drawing too

 

 

 

much output current, or duty

 

 

 

cycle is too high. Reduce output

 

 

 

current, duty cycle or both.

 

 

3.

There is internal damage to the

 

 

 

power source. Contact an autho-

 

 

 

rized Lincoln Electric Service

 

 

 

facility.

 

 

 

 

 

Machine will not power up (No lights)

1.

Make certain that the power

 

 

 

switch is in the "ON" position.

 

 

2.

Input voltage selection made

 

 

 

improperly. Power down, check

 

 

 

input voltage reconnect accord-

 

 

 

ing to diagram on reconnect

 

 

 

cover.

 

 

 

 

 

Machine won’t weld, can’t get any

1.

If the displays show an Err ###

 

output.

 

see the fault section for correc-

 

 

 

tive action.

 

 

2.

If the displays are not lit refer to

 

 

 

machine will not power up sec-

 

 

 

tion.

 

 

3.

If the thermal symbol is lit refer to

 

 

 

the thermal section.

 

 

 

 

 

Thermal symbol is lit

1.

Check for proper fan operation

 

 

2.

Check for material blocking

 

 

 

intake or exhaust louvers.

 

 

 

 

 

 

 

 

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER MIG 300

Page 30
Image 30
Lincoln Electric IM736-D Troubleshooting, Problems Possible Areas Symptoms Misadjustments, Recommended Course of Action