| TROUBLESHOOTING | |||
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | |||
|
|
|
|
|
| PROBLEMS |
| POSSIBLE | RECOMMENDED |
| (SYMPTOMS) |
| CAUSE | COURSE OF ACTION |
|
|
| ||
Engine will “crank” but not start. | 1. Air intake |
| ||
|
|
| Manually reset inside machine. |
|
|
| 2. | Out of fuel. Fill fuel tank. |
|
|
| 3. | Fuel shut off valve is in off posi- |
|
|
|
| tion. |
|
|
| 4. | Low battery voltage. |
|
|
|
| ||
Machine fails to hold the “heat” | 1. Rough or dirty commutator. |
| ||
constantly. |
|
|
| |
|
| 2. Brushes may be worn down to |
| |
|
|
| limit of life. |
|
|
| 3. | Brush springs may be broken. |
|
|
| 4. | Field circuit may have variable |
|
|
|
| resistance connections or intermit- |
|
|
|
| tent open circuit, due to loose con- |
|
|
|
| nections or broken wire. |
|
|
|
|
| If all recommended possible areas |
|
| 5. | Electrode or work lead connec- | of misadjustment have been |
|
|
| tions may be poor. | checked and the problem persists, |
|
|
|
| Contact your local Lincoln |
|
| 6. | Wrong grade of brushes may be | Authorized Field Service Facility. |
|
|
| installed on generator. |
|
|
| 7. | Field rheostat may be making |
|
|
|
| poor contact and overheating. |
|
|
| 8. | “Current Control” may not be |
|
|
|
| operating properly. |
|
|
| 9. | “Current Control” brushholder con- |
|
|
|
| tact springs may be worn out or |
|
|
|
| missing. Contact surface may be |
|
|
|
| dirty, rough and pitted. |
|
|
| 10. “Current Control” brushholder |
| |
|
|
| support stud and mating contact |
|
|
|
| surfaces may be dirty or pitted |
|
|
|
| and burned. |
|
|
| 11. Engine running at varying |
| |
|
|
| speeds. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.