D-4

MAINTENANCE

D-4

 

 

 

SPARK ARRESTOR

(for machines equipped with a separate spark arrest- ing unit)

WARNING

WARNING

Spark Arrestor and Muffler may be hot!

Allow engine to cool before servicing spark arrestor! Do not operate engine while servicing spark arrestor!

Service the spark arrestor every 100 hours of opera- tion or twice a year, which ever occurs first.Service as follows:

1.Stop engine and allow to cool

2.Loosen clamp and remove spark arrestor from machine.

3.Remove locknut on top of spark arrestor housing and lift off cap.

4.Separate plates and clean if necessary.

5.Inspect plates and housing for holes or cracks. Replace spark arrestor if damaged.

6.Assemble spark arrestor using reverse order: step 3, then step 2.

GFCI RECEPTACLE TESTING AND RESET- TING PROCEDURE

The GFCI receptacle should be properly tested at least once every month or whenever it is tripped. To properly test and reset the GFCI receptacle:

If the receptacle has tripped, first carefully remove any load and check it for damage.

If the equipment has been shut down, it must be restarted.

The equipment needs to be operating at high idle speed and any necessary adjustments made on the control panel so that the equipment is providing at least 80 volts to the receptacle input terminals.

The circuit breaker for this receptacle must not be tripped. Reset if necessary.

Push the "Reset" button located on the GFCI recep- tacle. This will assure normal GFCI operation.

Plug a night-light (with an "ON/OFF" switch) or other product (such as a lamp) into the GFCI receptacle and turn the product "ON".

Push the "Test" button located on the GFCI recepta- cle. The night-light or other product should go "OFF".

Push the "Reset" button, again. The light or other product should go "ON" again.

If the light or other product remains "ON" when the "Test" button is pushed, the GFCI is not working prop- erly or has been incorrectly installed (miswired). If your GFCI is not working properly, contact a qualified, certified electrician who can assess the situation, rewire the GFCI if necessary or replace the device.

SAE-400 SEVERE DUTY

Page 23
Image 23
Lincoln Electric IM870-A manual Spark Arrestor, Gfci Receptacle Testing and RESET- Ting Procedure

IM870-A specifications

The Lincoln Electric IM870-A is a cutting-edge industrial robotic welding machine that has garnered attention for its advanced features and capabilities. Designed for high-performance applications, this welding system stands out in the manufacturing environment due to its versatility, precision, and efficiency.

At its core, the IM870-A is equipped with a high-speed manipulator that can handle various welding processes, including MIG, TIG, and flux-cored welding. This flexibility allows manufacturers to adapt the machine for a wide range of materials, including steel, aluminum, and stainless steel. The machine's robust construction ensures durability, making it a reliable choice for demanding industrial applications.

One of the standout features of the IM870-A is its intelligent control system. This system utilizes advanced programming and software to optimize welding parameters in real-time, ensuring consistent weld quality and reducing the likelihood of defects. The machine incorporates Lincoln Electric's proprietary arc control technology, which enhances the stability and reliability of the welding arc, further contributing to improved weld quality.

In addition to its welding capabilities, the IM870-A offers a user-friendly interface that simplifies operation and programming. The machine is designed with intuitive controls, allowing operators to quickly adjust settings and switch between different welding processes. This ease of use is critical in busy production environments, where time and efficiency are of the essence.

Another noteworthy characteristic of the IM870-A is its integration with Industry 4.0 technologies. The machine supports connectivity through IoT (Internet of Things) protocols, enabling remote monitoring and data analysis. This feature allows manufacturers to track performance metrics in real-time, leading to better decision-making and maintenance planning. The analytics provided can identify trends and areas for optimization, ultimately improving overall operational efficiency.

Safety is also a priority in the design of the IM870-A. The machine is equipped with multiple safety features, including automatic shutdown protocols in case of malfunction and protective enclosures to safeguard operators from high-temperature processes.

In summary, the Lincoln Electric IM870-A is a sophisticated welding solution that combines versatility, advanced technology, and user-friendly operation. Its intelligent control systems, Industry 4.0 capabilities, and strong emphasis on safety make it a valuable asset for manufacturers looking to enhance their welding operations and maintain high standards of quality. Whether in automotive assembly, metal fabrication, or other industrial sectors, the IM870-A is an exemplary choice for modern welding needs.