B-4

OPERATION

B-4

 

 

 

ENGINE CONTROLS:

12.RUN/STOP SWITCH - RUN position ener- gizes the engine prior to starting. STOP position stops the engine. The oil pressure interlock switch prevents battery drain if the switch is left in the RUN position and the engine is not operating.

18. ENGINE PROTECTION LIGHT- A warning indi- cator light for Low Oil Pressure and/or Coolant Over Temperature.The light is off when the systems are func- tioning properly. The light will come on and the engine will shutdown when there is Low Oil Pressure and/or the Coolant is Over Temperature.

13. GLOW PLUG PUSH BUTTON -

When pushed activates the glow plugs. Glow plug should not be activated for more than 20 seconds continuously.

14.START PUSH BUTTON - Energizes the

starter motor to crank the engine.

15.IDLER SWITCH- Has two positions as follows:

1)In the HIGH position, the engine runs at the high idle speed controlled by the engine governor.

2)In the AUTO position, the idler operates as fol- lows:

When switched from HIGH to AUTO or after starting the engine, the engine will operate at full speed for approximately 12 seconds and then go to low idle speed.

When the electrode touches the work or power is drawn for lights or tools (approximately 100 Watts minimum), the engine accelerates and operates at full speed.

When welding ceases or the AC power load is turned off, a fixed time delay of approximately 12 seconds starts. If the welding or AC power load is not restarted before the end of the time delay, the idler reduces the engine speed to low idle speed.

The engine will automatically return to high idle speed when there is welding load or AC power load reapplied.

16.ELECTRIC FUEL GAUGE- The electric fuel

gauge gives accurate and reliable indication as to how much fuel is in the fuel tank.

17. ENGINE HOUR METER- Displays the total

time that the engine has been running. This meter is useful for scheduling prescribed maintenance.

TABLE B.2

TYPICAL VANTAGE® 500 (CE) FUEL CONSUMPTION

 

PERKINS (404C-22T), (404D-22T)

Running Time for 15 gallons / hours

 

Gal./Hr (Liters/Hr)

Codes 11298, 11299

Codes 11524, 11525

 

 

 

11574, 11575

Low Idle - No Load

.31(1.16)

49.13

65.50

1200 R.P.M.

 

 

 

High Idle - No Load

.47(1.78)

31.89

42.52

1575 R.P.M.

 

 

 

DC Weld Output

1.82(6.87)

8.26

11.01

450 Amps @ 38Volts

 

 

 

14,500 Watts 3 Phase

1.35(5.11)

11.11

14.81

 

 

 

 

NOTE: This data is for reference only. Fuel consumption is approximate and can be influenced by many factors, including engine maintenance, environmental conditions and fuel quality.

Note: The light remains off when the RUN-STOP switch is in the "ON" position prior to starting the engine.However if the engine is not started within 60 seconds the light will come on. When this happens the RUN-STOP switch must be returned to the "OFF" posi- tion to reset the engine protection system and light.

19. BATTERY CHARGING LIGHT- A warning indica- tor light for Low/No battery charge. The light is off when the systems are functioning properly. The light will come on if there is a Low/No battery condition but the machine will continue to run.

Note: The light may or may not come on when the RUN- STOP switch is in the "ON" position. It will come on dur- ing cranking and stay on until the engine starts. After starting the engine the light will go off unless a Low/No battery charge condition exists.

20. COOLANT TEMPERATURE GAUGE- A indica-

tor of engine coolant temperature.

21.OIL PRESSURE GAUGE- A indicator of engine Oil Pressure.

22.CIRCUIT BREAKER

STARTING THE ENGINE

1.Remove all plugs connected to the AC power recepta- cles.

2.Set IDLER switch to AUTO.

3.Press Glow Plug Button and hold 15 to 20 seconds.

4.Set the RUN/STOP switch to RUN.

5.Press START button until the engine starts or for up to 10 seconds. Continue to hold the glow plug button for up to an additional 10 seconds.

6.Release the engine START button immediately when the engine starts.

7.The engine will run at high idle speed for approximately 12 seconds and then drop to low idle speed. Allow the engine to warm up at low idle for several minutes before applying a load and/or switching to high idle. Allow a longer warm up time in cold weather.

VANTAGE® 500 (CE)

Page 22
Image 22
Lincoln Electric IM894-B manual Engine Controls, Glow Plug Push Button, Circuit Breaker Starting the Engine