Lincoln Electric IM911 O Off, Explanation Of Symbols That Appear On This Equipment, Installation

Models: IM911

1 26
Download 26 pages 23.36 Kb
Page 8
Image 8
INSTALLATION

 

 

A-1

INSTALLATION

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – COOL ARC® 40

 

 

 

Product No. / Model

K2187-2 (COOL ARC® 40 230V International)

 

 

 

 

 

 

Via Continental European (SCHUKO)- PRONG PLUG

 

 

 

 

 

 

 

 

 

 

 

 

Input

220-240VAC

50/60 Hz 1 Phase

 

 

 

 

 

 

 

 

 

 

 

Current Draw @ 60Hz Input

1.3-1.7 Amps

 

 

 

 

 

 

 

 

 

 

 

Current Draw @ 50Hz Input

2.0-2.4 Amps

 

 

 

 

 

 

 

 

 

 

 

Maximum Operating Pressure and Flow Rate

60 psi (414 kPa) (4.14 bar)Max.

 

 

 

(Open Flow, Without Welding Torch Restriction)

1.66 gal/min. (6.28 liter/min) Max.

 

 

 

 

 

 

 

 

 

 

 

Typical Operating Pressure and Flow Rate

53-57 psi (365-393 kPa)

 

 

 

(With Welding Torch Restriction)

.45-.60 gal/min. (1.7-2.3 liter/min)

 

 

 

 

 

 

 

 

 

 

 

Reservoir Size

2.0 ga. (7.6 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Above Freezing: Use Clean tap, distilled or de-ionized water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Below Freezing: Use 50% water and 50% pure ethylene glycol

 

 

 

 

 

 

(reagent

or industrial grade) mixture.

 

 

 

 

 

 

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.

 

 

 

Recommended Coolant

These coolants will damage the pump and block the small internal passageways of the

 

 

 

 

 

 

heat exchanger, affecting cooling performance. To acquire the proper coolant contact

 

 

 

 

 

 

a local welding distributor.

 

 

 

 

 

 

 

 

DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain

 

 

 

 

 

 

oil-based substances, which attack the plastic components of the cooler. Once added

 

 

 

 

 

 

to the cooler, these substances are impossible to purge from the water lines and heat

 

 

 

 

 

 

exchanger.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

46.5 lbs. (21.1 kg)

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

Reservoir

61.2 lbs. (27.8 kg)

 

 

 

 

 

 

 

 

 

 

Full (Water)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

9.03 in. (229.4mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

W

9.10 in. (231.1mm)

 

 

 

Dimensions

 

 

 

 

 

 

 

 

31.99 in. (812.6mm)

 

 

 

 

 

H (Top Face)

 

H Top Handle)

34.26 in. (870.2mm)

EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT

ON

OOFF

COOL ARC® 40

Page 8
Image 8
Lincoln Electric IM911 manual O Off, Explanation Of Symbols That Appear On This Equipment, Installation, Cool Arc