A-5

INSTALLATION

A-5

INSTALLATION OF WATER COOLED ACCESSORIES

After following the installation instructions above, the COOL ARC® 40 is ready for connection to a water- cooled accessory.

WATER COOLED TIG TORCH AND MIG GUN Follow Figure 2 when using the COOL ARC® 40 with water-cooled TIG torches. Follow Figure 4 when using the COOL ARC® 40 with water-cooled MIG gun. Consult the manufacturer's instruction manual when using the COOL ARC® 40 with other water- cooled TIG and MIG accessories.

CONNECTION TO WIRE FEEDERS

Follow Figure 3 when using the COOL ARC® 40 in conjunction with a wire feeder. Because the COOL ARC® 40 requires continuos flow the feeder will need to have pass-through water hoses installed in order to operate with the COOL ARC® 40. DO NOT USE A WATER SOLENOID VALVE with the COOL ARC®

40.Water pass-through connection kits are available for wire feeders. Refer to product literature or the wire feeder's instructions manual for kit availability and fur- ther connection details. It is not required to run the water lines through the wire feeder. If pass-through water hoses are unavailable, connect the MIG gun as shown in Figure 4.

CAUTION

DO NOT USE A WATER SOLENOID VALVE with the COOL ARC® 40. When a solenoid valve clos- es, the pump dead-head, causing the pump to heat up and will lead to premature failure of the pump.

------------------------------------------------------------------------

K529-10 POWER INPUT CABLE WITH WATER AND GAS HOSES

This cable assembly includes a (1) power cable, (1) control cable, (1) gas hose and (2) water hoses to connect a power source to a wire feeder. The cable length is 3.05 m (10 Ft.). The water hoses have 5/8"- 18 left hand male hose fittings and the gas hose has a 5/8"-18 right hand male hose fitting. The cable and hose lengths are designed to connect a wire feeder to a COOL ARC® 40 that is vertically mounted at the rear of a power source on a dual cylinder undercar- riage.

Refer to Figure 5 for an illustration of this connection.

FIGURE 4

Connection to Wire Feeder (Do Not Use Water Solenoid)

FIGURE 2

Water Cooled TIG Torch Connection

 

REGULATOR

 

FLOWMETER

 

ARGON GAS

 

CYLINDER

COOLANT

COOLANT

IN

OUT

POWER SOURCE

GAS*

COOLANT

COOLANT

IN

OUT

KP504-WATER HOSES AND FEMALE TO FEMALE 5/8" LH CGA ADAPTER COUPLINGS

KP1529-1

FEMALE TO FEMALE 5/8" LH CGA ADAPTER COUPLINGS (COUPLINGS ONLY)

COOLANT

COOLANT

GUN CABLE

GAS

 

COOLANT*

 

IN OUT

 

 

 

 

 

 

 

 

COOLANT*

 

 

 

FEMALE TO FEMALE*

 

 

 

 

 

 

 

 

 

POWER CABLE ADAPTER*

 

 

 

CGA FITTING

TIG TORCH

 

 

 

 

 

POWER / COOLANT

 

 

 

 

 

COOLANT

 

 

 

 

 

 

 

 

TO WORK

 

 

 

*INCLUDED IN

GAS

 

 

KP504 HOOK-UP KIT

FIGURE 3

Water Cooled MIG Gun Connection

COOLANT

COOLANT

COOLANT

 

 

 

OUT

 

 

 

IN

 

COOLANT

 

 

 

 

 

 

COOLANT

COOLANT

 

 

 

 

 

 

 

 

 

 

 

 

GUN CABLE

 

 

 

 

 

 

NOTE:

COOLANT

=

BLUE HOSE

 

 

 

 

OUT

 

 

KP504 FOR HOOK-UP

 

 

 

K1859-1 FOR WIRE

 

 

 

 

TO WIRE FEEDERS

 

COOLANT

=

RED HOSE

FEEDERS WITH QUICK

WITH CGA FITTINGS

 

IN

 

 

 

DISCONNECT FITTINGS

 

 

 

 

 

FIGURE 5

Connection to Wire Feeder (Do Not Use Water Solenoid)

SHIELDING

GAS

COOLANT

IN

COOLANT

OUT

CONTROL CABLE

COOLANT

 

 

 

 

IN

 

 

 

COOLANT

 

COOLANT

 

 

OUT

 

 

 

COOLANT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE CABLE

 

 

 

 

TO WORK

 

 

 

 

 

 

K529-10

 

 

 

 

GUN CABLE

 

 

 

 

 

 

NOTE:

 

NOTE:

 

 

 

ORDER K1859-1 ALONG WITH

 

 

 

 

K529-10 FOR WIRE FEEDERS

 

COOLANT

= BLUE HOSE

 

 

 

OUT

 

WITH QUICK DISCONNECT

 

 

 

 

 

COOLANT

 

 

FITTINGS.

 

= RED HOSE

 

 

 

IN

 

COOL ARC® 40

Page 12
Image 12
Lincoln Electric IM911 manual Installation of Water Cooled Accessories, Connection to Wire Feeders