Lincoln Electric IM917-A manual Installation, Power Wave 405M

Models: IM917-A

1 44
Download 44 pages 25.94 Kb
Page 10
Image 10

 

A-1

 

 

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE® 405M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

 

Product

Ordering

Input AC

Rated DC Output

Output

Weight

Dimensions

 

 

Name

Information

Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

 

 

 

 

 

 

50/60 Hz

(continuous)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350A

/ 34V / 60%

 

 

14.7”x12.5”x

 

 

Power

 

200-220/

3 Phase

 

 

27.8”*

 

 

Wave

K 2369-2

380-400/

320A

/ 33V / 60%

AMPS

86.5lbs

(373x318x

 

 

405M

 

415

1 Phase

5-425

(37.4 kg)

706*)mm

 

 

 

 

 

50/60 Hz

 

 

 

 

 

 

 

 

 

 

275A

/ 31V /100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Phase

 

 

 

 

 

 

 

 

 

300A / 32V / 100%

 

 

* Includes

 

 

 

 

 

 

3

Phase

 

 

handles

 

 

 

 

 

 

 

 

 

 

 

 

*Overall Length Including Handle, 21.6” (549mm) without handle. Insulation Class 180 (H)

POWER WAVE® 405M INPUT CURRENT

Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

 

Recommended

 

 

Voltage

Phases

300Amps@

 

 

350Amps@

Line Cord

Size Fuse Size

Notes

 

 

32Volts(100%)

 

 

34Volts(60%)

AWG SIZES

 

 

 

200

3

41

 

 

48

6

80A

Note 2

 

220

3

37

 

 

48

6

80A

Note 2

380

3

23

 

 

28

8

50A

 

 

400

3

22

 

 

27

8

50A

 

 

415

3

22

 

 

26

8

50A

 

 

 

 

 

 

 

 

 

 

Voltage

Phases

275Amps@

 

320Amps@

Line Cord

Size Fuse Size

Notes

 

 

31Volts(100%)

 

33Volts(60%)

 

 

 

 

200

1

----

 

 

----

---

-----

Note 1

220

1

64

 

 

82

4

125A

Note 2

380

1

44

 

 

55

6

80A

Note 2

400

1

40

 

 

50

8

80A

 

 

415

1

38

 

 

48

8

80A

 

 

 

 

 

 

 

 

 

 

 

 

1.Not rated is indicated by 4-x's in the box on the rating plate

2.When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select the output cable size based upon the following chart.

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:

 

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

 

 

100%

275

1/0

1/0

 

 

60%

350

1/0

2/0

 

POWER WAVE® 405M

Page 10
Image 10
Lincoln Electric IM917-A manual Installation, Power Wave 405M