Lincoln Electric IM959 manual Installation, Temperature Conversion Chart Celcius ºC Fahrenheit ºF

Models: IM959

1 22
Download 22 pages 28.69 Kb
Page 8
Image 8

A-1

 

INSTALLATION

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – COOL ARC

35

 

 

 

 

 

 

 

®

 

 

 

Product No. / Model

 

 

 

K2630-1 COOL ARC® 35

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

350VDC (From V310-T AC/DC & V311-T AC/DC)

 

 

 

 

 

 

 

 

 

 

 

 

Current Draw

 

 

 

 

0.35 Amps

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Operating Pressure and Flow Rate

 

 

 

50 psi (345 kPa) (3.5 bar)Max.

 

(Open Flow, Without Welding Torch Restriction)

 

 

 

1.2 gal/min. (4.6 liter/min) Max.

 

 

 

 

 

 

 

 

 

 

 

 

Typical Operating Pressure and Flow Rate

 

 

 

53-57 psi (365-393 kPa)

 

 

 

(With Welding Torch Restriction)

 

 

 

.45-.60 gal/min. (1.7-2.3 liter/min)

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir Size

 

 

 

1.3 gal. ( 5 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Above Freezing: Clean tap, distilled or de-ionized water.

 

 

 

 

 

 

 

 

 

 

 

 

For Use Below Freezing: 50% water and 50% pure ethylene glycol (reagent

 

 

 

 

 

 

 

or industrial grade) mixture.

 

 

 

 

 

 

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.

 

Recommended Coolant

These coolants will damage the pump and block the small internal passageways of

 

 

 

 

the heat exchanger, affecting cooling performance. To acquire the proper coolant

 

 

 

 

contact a local welding distributor.

 

 

 

 

 

 

DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain

 

 

 

 

oil-based substances, which attack the plastic components of the cooler. Once added

 

 

 

 

to the cooler, these substances are impossible to purge from the water lines and heat

 

 

 

 

exchanger.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

 

 

 

29.8 lbs. (13.5 kg)

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir

 

 

 

42.0 lbs. (19.0 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

Full (Water)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

24.5 in. (622 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

11.0 in. (280 mm)

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0 in. (256 mm)

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Conversion

 

 

 

 

 

 

 

 

Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Celcius ºC*

Fahrenheit ºF

 

 

 

 

 

 

 

 

20

 

68

 

 

 

 

 

 

 

 

30

 

86

 

 

 

 

 

 

 

 

40

 

104

 

 

 

 

 

 

 

 

50

 

122

 

 

 

 

 

 

 

 

60

 

140

 

 

 

 

 

 

 

 

70

 

158

 

 

 

 

 

 

 

 

80

 

176

 

 

 

 

 

 

 

 

90

 

194

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL ARC® 35

Page 8
Image 8
Lincoln Electric IM959 manual Installation, Temperature Conversion Chart Celcius ºC Fahrenheit ºF