A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS – R3R 600-I K1381-[ ]

INPUT - THREE PHASE ONLY

Standard Voltage Frequency

220-230V/50/60Hz

380-400V/50/60Hz

440-460V/50/60Hz

Rated Input Current

(Volts/Hz)

103A @ 600A Output

92A @ 500A Output } (220V/50/60Hz)

68A @ 375A Output

Duty Cycle

100%

60%

35%

Current Range

DC RATED OUTPUT

Amps

Volts at Rated Amperes

375

35

500

40

600

44

OUTPUT

 

 

Maximum Open Circuit Voltage

75-625 Amps

64VDC

POWER FACTOR @ RATED LOAD

.74 @ 500A

IDLE CURRENT

11.3@220V/50Hz

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-40°C to +40°C

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

27.5 in

22.3 in

32.0 in

446 lbs.

699 mm

566 mm

813 mm

203 kg.

 

 

 

 

Insulation Class: 155°C (F)