TROUBLESHOOTING

E-5

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

Output without control -

Continuity test. (Note B Pg. E-2).

1.Make continuity test outlined in Step 3,

one mode

 

 

on page E-2 except turn voltage con-

 

 

 

 

trol from maximum (0 ohms) to mini-

 

 

 

 

mum (10,000 ohms).

 

 

 

 

2.Replace Control Board #2. (Note A Pg. E-2).

 

 

 

 

Output without control -

 

 

l. Replace Control Board #2

both modes

 

 

2.Replace Control Board #1. (Note A Pg. E-2).

 

 

 

Output low in both modes -

Test rotor voltage (80-90 volts DC)

1.Rotor Voltage less than 80-90 volts DC

open circuit voltage low (CV and VV

 

 

a)Check Diodes D1 - D2 - D5 -D6. See

positions)

 

 

Procedure.

 

 

 

 

b)Check SCR Bridge. See Procedure.

 

 

 

 

c)Check resistance of rotor fields.

 

 

 

 

Normal value about 14 ohms.

 

 

 

 

2.Rotor Voltage Within Limits

 

 

 

 

a)Check SCR Bridge. See Procedure.

 

 

 

 

b)Check generator field coil resis-

 

 

 

 

tance.

 

 

 

 

1)Disconnect blue and brown

 

 

 

 

field coil leads. Normal value

 

 

 

 

about 10 ohms. One field coil

 

 

 

 

open - 20 ohms. Both field

 

 

 

 

coils open - infinite resistance.

 

 

 

 

Arc difficult to start in CV position

Test alternator outputs

(22-24

1.Set polarity switch in electrode positive

using low current and voltage

volts DC)

 

position.

(Characterized by large droplets, low

 

 

2.Check voltage between work stud and

frequency transfer)

 

 

positive alternator lead connected to

 

 

 

 

input side of line contactor.

 

 

 

 

a)Within Limits

 

 

 

 

Check contactor contacts.

 

 

 

 

b)Less than 22-24 volts DC

 

 

 

 

Check three phase bridge recti-

 

 

 

 

fier diodes D7 - D8 -D9 -D10 -

 

 

 

 

D11 -D12. See Procedure.

 

 

 

 

 

CAUTION