OPTIONAL

CONTROL PANELS

PROCEDURE CONTROL PANELS

POWER FEED 10

DUAL PROCEDURE PANEL

This panel stores two procedures in memory. The user may select procedure “A” or “B” at the switch with a separate gun mounted switch, or while welding with any welding gun.

Order K1542-5.

DUAL PROCEDURE / MEMORY

Six different welding procedures and processes may be stored for recall. Includes Dual Procedure. Memories 2-6 may be accessed with an “open air” trigger pull using any welding gun.

Order K1542-9.

POWER FEED 10 DUAL

DUAL PROCEDURE / MEMORY

Four welding procedures and processes may be stored for recall. Includes Dual Procedure for each wire drive. Gun 1 and 2 have 2 procedures each, and each have access to 4 more from memory.

Order K1542-13.

DUAL HEAD SELECT PANEL

Allows control box (K1539-2) to control two separate wire drives (K1540-2). Comes standard with Power Feed 10 Dual . Optional on Power Feed 10.

Order K1542-14