Danish Interpretation Systems

User Manual

Max. number of units to be connected

The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a

CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.

CM/DM 60x0P Chairman/Delegate Units

Length of Feeding Cable

Length of inter connecting

Total cable length

Max. number of CM/DM

Type CAT5 AWG24

Cable, Type CAT5 AWG24

 

60x0 pr output

 

 

 

 

10 m

1 m

51 m

42

30 m

1 m

67 m

38

50 m

1 m

83 m

34

100 m

1 m

123 m

24

150 m

1 m

165 m

16

10 m

2 m

88 m

40

30 m

2 m

98 m

35

50 m

2 m

108 m

30

100 m

2 m

142 m

22

150 m

2 m

180 m

16

CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box

This configuration shows two CM/DM 60x0 Delegate/Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB

6002. Maximum 5 m cable from JB 6002 to CM/DM 60x0 and max. one CM/DM 60x0 on each output of JB 6002.

Length of Feeding Cable,

Length of Cable between each

Total cable

Number of

Max. number of

Type CAT5 AWG24

JB 6002, Type CAT5 AWG24

length

JB 6002

DM 60x0

 

 

 

 

 

10 m

3 m

61 m

18

36

30 m

3 m

75 m

16

32

50 m

3 m

89 m

14

28

100 m

3 m

127 m

10

20

150 m

3 m

168 m

7

14

10

Manual 01 18 04450

 

Page 10
Image 10
Listen Technologies PS 6000 user manual Max. number of units to be connected, CM/DM 60x0P Chairman/Delegate Units