Danish Interpretation Systems

User Manual

CM/DM 6060F/6510F Chairman/Delegate Units

The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a

CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.

Length of Feeding Cable

Length of inter connecting

Total cable length

Max. number of

Type CAT5 AWG24

Cable, Type CAT5 AWG24

 

CM/DM 60x0 pr output

 

 

 

 

10 m

1 m

39 m

30

30 m

1 m

56 m

27

50 m

1 m

73 m

24

100 m

1 m

115 m

16

150 m

1 m

160 m

11

10 m

2 m

64 m

28

30 m

2 m

78 m

25

50 m

2 m

94 m

23

100 m

2 m

130 m

16

150 m

2 m

170 m

11

CM/DM 6560F Chairman/Delegate Units

Length of Feeding Cable

Length of inter-connecting

Total cable length

Max. number of CM/DM

Type CAT5 AWG24

Cable, Type CAT5 AWG24

 

60x0 pr output

 

 

 

 

10 m

1 m

35 m

27

30 m

1 m

53 m

24

50 m

1 m

70 m

21

100 m

1 m

113 m

14

150 m

1 m

159 m

10

10 m

2 m

58 m

25

30 m

2 m

72 m

22

50 m

2 m

88 m

20

100 m

2 m

126 m

14

150 m

2 m

166 m

9

Manual 01 18 04450