Danish Interpretation Systems | User Manual |
CM/DM 6060F/6510F Chairman/Delegate Units
The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.
Length of Feeding Cable | Length of inter connecting | Total cable length | Max. number of |
Type CAT5 AWG24 | Cable, Type CAT5 AWG24 |
| CM/DM 60x0 pr output |
|
|
|
|
10 m | 1 m | 39 m | 30 |
30 m | 1 m | 56 m | 27 |
50 m | 1 m | 73 m | 24 |
100 m | 1 m | 115 m | 16 |
150 m | 1 m | 160 m | 11 |
10 m | 2 m | 64 m | 28 |
30 m | 2 m | 78 m | 25 |
50 m | 2 m | 94 m | 23 |
100 m | 2 m | 130 m | 16 |
150 m | 2 m | 170 m | 11 |
CM/DM 6560F Chairman/Delegate Units
Length of Feeding Cable | Length of | Total cable length | Max. number of CM/DM |
Type CAT5 AWG24 | Cable, Type CAT5 AWG24 |
| 60x0 pr output |
|
|
|
|
10 m | 1 m | 35 m | 27 |
30 m | 1 m | 53 m | 24 |
50 m | 1 m | 70 m | 21 |
100 m | 1 m | 113 m | 14 |
150 m | 1 m | 159 m | 10 |
10 m | 2 m | 58 m | 25 |
30 m | 2 m | 72 m | 22 |
50 m | 2 m | 88 m | 20 |
100 m | 2 m | 126 m | 14 |
150 m | 2 m | 166 m | 9 |
Manual 01 18 04450 | 11 |
|