Listen Technologies PS 6000 MU 6040 C/D without connected loudspeaker, Is 6132P Interpreter Units

Models: PS 6000

1 14
Download 14 pages 57.3 Kb
Page 12
Image 12

Danish Interpretation Systems

User Manual

MU 6040 C/D without connected loudspeaker

This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no

loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0 above.

Length of Feeding Cable,

Cable length between

Total cable length

Max. number of

Type CAT5 AWG24

each MU 6040

 

MU 6040

 

 

 

 

10 m

2 m

168 m

80

30 m

2 m

178 m

75

50 m

2 m

188 m

70

100 m

2 m

200 m (202 m)

51 (52*)

150 m

2 m

200 m (232 m)

26 (42*)

100 m

1 m

151 m

52

150 m

1 m

191 m

42

Numbers in (‘) are the number of units, which could have been connected CU/EX, but where the total

number of units has been lowered due to the restriction of the maximum length of cable (200 m).

IS 6132P Interpreter Units

This table shows the maximum number of IS 6132P Interpreter Sets, which can be connected. The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).

If loudspeakers are used, then use the figures for CM/DM 60x0 above.

Note: The number of units is dependant of how many interpreter sets there are per booth (or language), as there only can be one set switched ON per language (channel).

Length of Feeding Cable,

Length of inter-connecting Cables,

Max. number of units pr output

Type CAT5 AWG24

Type CAT5 AWG24

All ON ½ ON 1/3 ON

 

 

 

 

 

 

10m

2

m

54

x

x

30m

2

m

49

57

60

50m

2

m

44

51

x

100m

2

m

35

40

x

150m

2

m

25

30

x

12

Manual 01 18 04450

 

Page 12
Image 12
Listen Technologies PS 6000 user manual MU 6040 C/D without connected loudspeaker, Is 6132P Interpreter Units