Danish Interpretation Systems | User Manual |
MU 6040 C/D without connected loudspeaker
This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no
loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0 above.
Length of Feeding Cable, | Cable length between | Total cable length | Max. number of |
Type CAT5 AWG24 | each MU 6040 |
| MU 6040 |
|
|
|
|
10 m | 2 m | 168 m | 80 |
30 m | 2 m | 178 m | 75 |
50 m | 2 m | 188 m | 70 |
100 m | 2 m | 200 m (202 m) | 51 (52*) |
150 m | 2 m | 200 m (232 m) | 26 (42*) |
100 m | 1 m | 151 m | 52 |
150 m | 1 m | 191 m | 42 |
Numbers in (‘) are the number of units, which could have been connected CU/EX, but where the total
number of units has been lowered due to the restriction of the maximum length of cable (200 m).
IS 6132P Interpreter Units
This table shows the maximum number of IS 6132P Interpreter Sets, which can be connected. The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).
If loudspeakers are used, then use the figures for CM/DM 60x0 above.
Note: The number of units is dependant of how many interpreter sets there are per booth (or language), as there only can be one set switched ON per language (channel).
Length of Feeding Cable, | Length of | Max. number of units pr output | |||
Type CAT5 AWG24 | Type CAT5 AWG24 | All ON ½ ON 1/3 ON | |||
|
|
|
|
|
|
10m | 2 | m | 54 | x | x |
30m | 2 | m | 49 | 57 | 60 |
50m | 2 | m | 44 | 51 | x |
100m | 2 | m | 35 | 40 | x |
150m | 2 | m | 25 | 30 | x |
12 | Manual 01 18 04450 |
|