System Setup

Danish Interpretation Systems

User Manual

 

 

System Setup

General guidelines

Connect the RP 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines:

Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.

Maximum cable length in one chain when using repeaters is 650 m.

As the RP 6004 Repeater is repeating only one of the four outputs A (A1 or A2) or B

(B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and 4) is totally max. 16.

If more languages are required, Interpreter sets for those languages have to be divided between both chains (A or B) on the CU 6010. Normally the languages are supposed to be divided equally on chains A (A1 or A2) and B (B1 or B2).

If the last unit in one chain is a CS 6032 Channel Selector, this unit has to be terminated with an external termination, as the CS 6032 does not have an internal termination.

Built into 19” Racks

The optional 19”-Brackets allow the unit to be mounted in a rack with either the front (connector side) or the blank backside to the front side of the rack. The height is 1HU and allows units to be stacked using only 44mm rack height.

Can also be mounted at the back of the rack cabinet freeing the space at the front of the rack. The cabinet shall then be deep enough to allow this.