Danish Interpretation Systems | User Manual |
|
|
qPower LED
Those LED light up when Power is available on the connector next to the LED
qIncoming data LED
Those LED flashes, when the unit receives incoming data from connected units on the connector next to the LED.
System design
There are no settings to be done on the RP 6004 Repeater.
However it is important to observe, that the unit is only repeating one of the chains on the CU 6010 Central Unit.
And as so, the specification, which applies to each of the chain outputs on the CU 6010 Central Units does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004 Repeaters, bare in mind, that as the RP 6004
Repeater is repeating only one of the four outputs A (A1 or A2) or B (B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and 4) is totally max. 16.
If more languages are required, Interpreter sets for those languages have to be connected either to an other RP 6004 Repeater, which is connected to the other of the two chains (A or B) on the CU 6010, or directly to the other of the two chains (A or B) on a CU 6010.
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU 6010 the first RP 6004 is connected to the ‘Loop through’ connector. The next RP 6004 Repeaters can be connected to either the other ‘Loop through’ connector or to one of the ‘Repeated out’ connectors. If using the ‘Repeated’ outputs
maximum two more RP 6004 Repeaters can be connected extending the maximum cable length in one chain up to 650 m. The above schematic is showing the connection using the ‘‘Repeated out’ connectors.
8 | Manual 01 18 04466 |
|