ALTERNATE PROGRAMMING METHOD

FUNCTION CODE

LOCAL PROGRAMMING

 

TELEPHONE PROGRAMMING

31

Step 1 Enter Function Code 31, then press #.

Step 1

Enter Function Code 31 and

 

 

 

 

press #, one short beep sounds.

ADD A

 

ACCESS CODE:

 

 

 

 

 

Step 2

Enter the new 4-digit Stand-alone Access

STAND-ALONE

 

 

 

Step 2 Enter the new 4-digit Stand-alone

 

Code, press #, one short beep sounds.

ACCESS CODE

 

Access Code, then press #.

Step 3

Enter the new 4-digit Stand-alone

A Stand-alone Access Code is

 

 

 

 

Access Code again for verifi cation.

a number entered at the AE-100

 

ACCESS CODE:

 

 

keypad to request access. Up to

 

 

 

Step 4

Press #, two short beeps sound.

125 4-digit Stand-alone Access

 

 

 

Step 3 Enter the new 4-digit Stand-alone

 

 

Codes can be set.

 

 

NOTE: Each Stand-alone Access

Access Code again for verifi cation

 

 

Code programmed reduces the

Step 4 Press #.

 

 

possible number of Directory

 

 

 

 

 

Entries by one.

 

 

 

 

 

 

 

 

 

 

 

33

Step 1 Enter Function Code 33, then press #.

Step 1

Enter Function Code 33 and

 

 

 

 

press #, one short beep sounds.

DELETE A

 

ACCESS CODE:

 

 

 

 

 

 

 

 

 

Step 2

Enter the 4-digit Stand-alone Access Code

STAND-ALONE

 

 

 

Step 2 Enter the 4-digit Stand-alone Access

 

to delete, press #, one short beep sounds.

ACCESS CODE

 

Code to delete, then press #.

Step 3

Enter the 4-digit Stand-alone Access

Deletes a single existing

 

 

 

 

Code to delete again for verifi cation.

Stand-alone Access Code.

 

ACCESS CODE:

 

 

 

 

 

 

Step 4

Press #, two short beeps sound.

 

Step 3 Enter the 4-digit Stand-alone Access

 

 

 

Code to delete again for verifi cation

 

 

 

Step 4 Press #.

 

 

 

 

 

 

 

 

34

Step 1 Enter Function Code 34, then press #.

Step 1

Enter Function Code 34 and

 

 

 

 

press #, one short beep sounds.

COPY ALL MASTER

 

UNITS:

 

 

 

 

 

Step 2

Enter the number(s) (2, 3, and/or 4)

MEMORY TO

 

 

 

Step 2 Enter the number(s) (2, 3, and/or 4) of all the

 

of all the sub-units to copy the data to,

SUB-UNITS

 

sub-units to copy the data to, then press #.

 

then press #, one short beep sounds.

To synchronize programming

 

 

 

 

Step 3

Enter 5 for verifi cation, then press #,

in multi-unit installations, all

 

ARE YOU SURE ? 5

 

system data can copied from the

 

 

 

 

two short beeps sound. (Any entry other

master unit to selected sub-units.

 

 

 

 

than 5# will cancel the command.)

Step 3 Enter 5 for verifi cation, then press #.

 

This data includes the Directory

NOTE: To allow for multi-unit network

Entries, Stand-alone Access

- OR -

Codes, and all system option

 

communications, when executing this

Enter to cancel this command.

 

settings (except the sub-unit

 

command remotely over the telephone,

number).

 

 

 

 

NOTE: The installer must setup the system as a multi-unit

 

the system will disconnect your call

NOTE: This utility command

 

installation before this command will operate.

 

after Step #3 then copy the data from

can only be performed from the

 

 

 

 

 

the master unit to the sub-units.

“master” unit

 

 

 

 

CAUTION: This utility

 

 

 

 

 

command will overwrite ALL

 

 

 

 

 

data in the sub-unit(s) selected.

 

 

 

 

 

38

Step 1 Enter Function Code 38, then press #.

 

 

 

 

 

 

 

SYSTEM DISPLAY

 

LANGUAGE: 1-4

 

 

 

 

 

 

 

 

LANGUAGE

 

 

 

 

 

Step 2 Enter:

 

 

The factory default language is

 

 

1 for English (Default).

 

 

English. Three other languages

 

NOT AVAILABLE

can be selected as the language

2 for Spanish.

 

 

for the user and programming

 

 

displays.

3 for French.

 

 

NOTE: The system supports one

4 for Portuguese.

 

 

display language at a time.

 

 

 

 

 

 

 

 

Step 3 Press #.

 

 

18

Page 18
Image 18
Linear AE-100 manual ADD a, Stand-Alone, Access Code, Delete a, Copy ALL Master, Memory to, System Display, Language

AE-100 specifications

The Linear AE-100 is an advanced sound reinforcement amplifier, renowned for its superior performance and cutting-edge technology. Designed for both professional and personal use, the AE-100 possesses features that appeal to audio enthusiasts and professionals alike, making it a versatile choice for various applications including live performances, home theaters, and installations.

One of the standout features of the Linear AE-100 is its high power output, which ensures clear and powerful sound delivery even in large venues. It typically boasts an impressive output of up to 100 watts per channel, allowing it to handle the demands of large speaker systems without distortion. This attribute makes the AE-100 suitable for dynamic audio environments, where precision and clarity are paramount.

The amplifier incorporates advanced protection circuitry, preventing damage from overheating, short circuits, or overloading. This protective technology enhances the longevity and reliability of the device, allowing users to perform confidently without worrying about equipment failure during crucial events.

The AE-100 also supports both balanced and unbalanced input options, providing versatility in connectivity. The balanced XLR inputs help reduce noise interference, particularly over long cable runs, while the unbalanced 1/4” inputs cater to a variety of equipment setups. This adaptability enables it to integrate seamlessly with a wide range of sound sources, from microphones to musical instruments and playback devices.

Moreover, the device features an intelligent cooling system that maintains optimal operating temperatures. With a design that prioritizes airflow and heat dissipation, the AE-100 can sustain extended periods of use without compromising performance, making it ideal for lengthy performances or all-day events.

The Linear AE-100 also boasts a sleek and modern design, featuring a user-friendly interface with clearly labeled controls for ease of operation. Its build quality reflects durability, designed to withstand the rigors of both touring and fixed installations.

In summary, the Linear AE-100 is a powerful and efficient amplifier packed with features that cater to the needs of audio professionals and enthusiasts. With its robust power output, advanced protection mechanisms, versatile connectivity options, and intelligent cooling system, it stands out as a reliable choice for anyone seeking high-quality audio performance. Whether for live sound applications or home audio systems, the AE-100 delivers exceptional sound quality and reliability.