ALTERNATE PROGRAMMING METHOD

Alternate Programming Section

To make it easy for installers familiar with Linear’s and other manufacturer’s access control systems, two methods of programming are available. Function Codes that match other equipment help the installer to make quick programming changes with keystrokes they have used before.

Alternate Programming Method Selection

The Programming Position Numbers (or Function Codes) change depending on the programming method used. Refer to the table on Page 13 for the numbers used for each programming method.

PRESS

AND

TOGETHER

 

FOR

 

ALTERNATE PROGRAMMING METHOD

The keys used to enter programming from the unit’s keypad select which programming method is used for the current programming session.

Entering programming by pressing & keys together will select the Alternate Programming Method (other manufacturer’s style). Details of each programming step when using the Alternate Programming Method are shown on Pages 15-21.

Alternate Audio Prompts

The audio prompts that give feedback during programming at the unit’s keypad or over the telephone are different for the Alternate Programming Method. Those differences are shown in the table to the right.

Alternate Alphanumeric Entry

When the keypad is used for alphanumeric data entry in the alternate programming mode, each key enters data differently than the standard interface mode. See the keypad fi gure to the right.

Alternate Programming Access from the Keypad

1.Press & keys at the same time, then release.

2.The display will show [Master Code:].

3.Enter the master code (factory setting is 123456).

4.The display will show asterisks as the code is entered.

5.If the master code is incorrect, the system will sound two long beeps and return to normal operating mode.

6.If the password is correct, the display will show [SELECT FUNCTION:].

7.Programming commands can now be entered on the keypad. Refer to the following pages in this manual for Alternate Programming Method step details.

Re-entering a Command After a Mistake

If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad press and start the programming step over again.

Exiting Alternate Programming Mode

1. Press:

NOTE: The AE-100 will automatically exit Programming Mode after fi ve minutes of programming inactivity.

AUDIO PROMPTS FOR EACH PROGRAMMING METHOD

 

ALTERNATE

STANDARD

CONDITION

METHOD

METHOD

 

SOUND

SOUND

 

TWO

ONE

AFTER AN INCORRECT ENTRY

LONG

LONG

 

BEEPS

BEEP

AFTER A CORRECT ENTRY OF AN

ONE

TWO

SHORT

SHORT

INTERIM STEP

BEEP

BEEPS

 

AFTER A COMPLETE COMMAND

TWO

THREE

SHORT

SHORT

HAS BEEN ENTERED CORRECTLY

BEEPS

BEEPS

 

 

THREE

NO

EXITING PROGRAMMING MODE

SHORT

BEEPS

 

BEEPS

SOUND

ALTERNATE INTERFACE KEYPAD ALPHANUMERIC ENTRY

(FOR PROGRAMMING STEPS REQUIRING TEXT)

Q Z - , . ' *

A B C a b c

q z 0 1 2 3

 

 

 

 

D E F d e f

 

 

 

 

4 5 6 7 8 9

 

 

 

 

 

 

 

 

 

J K L j k l

 

G H I h g i

M N O m n o

T U V t u v

 

P R S p r s

W X Y w x y

erase

move to

next letter

entire entry

or finish

 

 

space

ENTER # AFTER EACH LETTER TO MOVE TO THE NEXT CHARACTER

FINISH COMPLETE ENTRY BY ENTERING ##

PRESS 8 THEN 0 TO BACKSPACE

PRESS STAR TO ERASE ENTIRE ENTRY

14

Page 14
Image 14
Linear AE-100 manual Alternate Programming Section

AE-100 specifications

The Linear AE-100 is an advanced sound reinforcement amplifier, renowned for its superior performance and cutting-edge technology. Designed for both professional and personal use, the AE-100 possesses features that appeal to audio enthusiasts and professionals alike, making it a versatile choice for various applications including live performances, home theaters, and installations.

One of the standout features of the Linear AE-100 is its high power output, which ensures clear and powerful sound delivery even in large venues. It typically boasts an impressive output of up to 100 watts per channel, allowing it to handle the demands of large speaker systems without distortion. This attribute makes the AE-100 suitable for dynamic audio environments, where precision and clarity are paramount.

The amplifier incorporates advanced protection circuitry, preventing damage from overheating, short circuits, or overloading. This protective technology enhances the longevity and reliability of the device, allowing users to perform confidently without worrying about equipment failure during crucial events.

The AE-100 also supports both balanced and unbalanced input options, providing versatility in connectivity. The balanced XLR inputs help reduce noise interference, particularly over long cable runs, while the unbalanced 1/4” inputs cater to a variety of equipment setups. This adaptability enables it to integrate seamlessly with a wide range of sound sources, from microphones to musical instruments and playback devices.

Moreover, the device features an intelligent cooling system that maintains optimal operating temperatures. With a design that prioritizes airflow and heat dissipation, the AE-100 can sustain extended periods of use without compromising performance, making it ideal for lengthy performances or all-day events.

The Linear AE-100 also boasts a sleek and modern design, featuring a user-friendly interface with clearly labeled controls for ease of operation. Its build quality reflects durability, designed to withstand the rigors of both touring and fixed installations.

In summary, the Linear AE-100 is a powerful and efficient amplifier packed with features that cater to the needs of audio professionals and enthusiasts. With its robust power output, advanced protection mechanisms, versatile connectivity options, and intelligent cooling system, it stands out as a reliable choice for anyone seeking high-quality audio performance. Whether for live sound applications or home audio systems, the AE-100 delivers exceptional sound quality and reliability.