ALTERNATE PROGRAMMING METHOD

FUNCTION CODE

LOCAL PROGRAMMING

TELEPHONE PROGRAMMING

74

Step 1 Enter Function Code 74, then press #.

 

 

 

 

 

AUTOMATIC

 

AUTO-ANSWER=1:

 

 

 

 

 

 

TELEPHONE

 

 

 

 

Step 2 The display will show the auto answer setting.

 

ANSWER

 

Enter 0 to disable auto answer.

 

The factory setting will allow the

 

Enter 1 to enable auto answer (default).

 

system to detect a ring signal on

NOT AVAILABLE

the telephone line and answer

Step 3 Press #.

 

the call.

 

 

 

 

NOTE: The automatic answer

 

 

 

 

feature can be turned off,

 

 

 

 

although remote programming,

 

 

 

 

remote access control by

 

 

 

 

residents, and resident call-back

 

 

 

 

features will no longer function

 

 

 

 

 

 

 

 

 

75

Step 1 Enter Function Code 75, then press #.

Step 1 Enter Function Code 75 and

 

 

 

press #, one short beep sounds.

SPEAKER CHIRP

 

BEEP ON=1 OFF=0

 

 

 

 

 

 

 

Step 2 Enter 0 to turn the keystroke chirps OFF.

ON KEYSTROKES

 

 

 

Step 2 Enter 0 to turn the keystroke chirps OFF.

Enter 1 to turn the keystroke chirps ON.

The factory setting will cause

Enter 1 to turn the keystroke chirps ON (default).

Step 3 Press #, two short beeps sound.

the speaker to chirp when each

key on the keypad is pressed.

Step 3 Press #.

 

Alternately, the speaker chirp can

 

 

 

 

be turned off.

 

 

 

 

76

Step 1 Enter Function Code 76, then press #.

Step 1 Enter Function Code 76 and

 

 

 

press #, one short beep sounds.

SPEAKER TONE

 

UNLOCK BEEP(1,0)

 

 

 

 

 

 

 

Step 2 Enter 0 to turn the relay tone OFF.

ON ACCESS RELAY

 

 

 

Step 2 Enter 0 to turn the relay tone OFF.

Enter 1 to turn the relay tone ON.

ACTIVATION

Enter 1 to turn the relay tone ON (default).

Step 3 Press #, two short beeps sound.

The factory setting will cause the

Step 3 Press #.

 

speaker to sound a tone for two

 

seconds when the access relay

 

 

 

 

is activated. Alternately, the tone

 

 

 

 

can be turned off.

 

 

 

 

 

 

 

 

 

77

Step 1 Enter Function Code 77, then press #.

 

 

 

 

 

RESIDENT

 

ENA=1 DISA=0:

 

 

 

 

 

 

CONTROL OF

 

 

 

 

Step 2 Enter 0 to disable resident control of the access

 

ACCESS RELAY

 

relay.

 

The factory setting allows the

 

Enter 1 to enable resident control

 

resident to activate the access

NOT AVAILABLE

of the access relay (default).

relay by pressing the 9 key on

 

their telephone when a call from

Step 3 Press #.

 

the AE-100 is received. This

 

 

 

 

 

feature can be disabled. Disabling

 

 

 

 

this feature will only allow access

 

 

 

 

by using resident Access Codes

 

 

 

 

and Stand-alone Access Codes

 

 

 

 

at the unit’s keypad.

 

 

 

 

 

 

 

 

 

20

Page 20
Image 20
Linear AE-100 manual Automatic, Telephone, Answer, Speaker Chirp, On Keystrokes, Speaker Tone, On Access Relay, Activation

AE-100 specifications

The Linear AE-100 is an advanced sound reinforcement amplifier, renowned for its superior performance and cutting-edge technology. Designed for both professional and personal use, the AE-100 possesses features that appeal to audio enthusiasts and professionals alike, making it a versatile choice for various applications including live performances, home theaters, and installations.

One of the standout features of the Linear AE-100 is its high power output, which ensures clear and powerful sound delivery even in large venues. It typically boasts an impressive output of up to 100 watts per channel, allowing it to handle the demands of large speaker systems without distortion. This attribute makes the AE-100 suitable for dynamic audio environments, where precision and clarity are paramount.

The amplifier incorporates advanced protection circuitry, preventing damage from overheating, short circuits, or overloading. This protective technology enhances the longevity and reliability of the device, allowing users to perform confidently without worrying about equipment failure during crucial events.

The AE-100 also supports both balanced and unbalanced input options, providing versatility in connectivity. The balanced XLR inputs help reduce noise interference, particularly over long cable runs, while the unbalanced 1/4” inputs cater to a variety of equipment setups. This adaptability enables it to integrate seamlessly with a wide range of sound sources, from microphones to musical instruments and playback devices.

Moreover, the device features an intelligent cooling system that maintains optimal operating temperatures. With a design that prioritizes airflow and heat dissipation, the AE-100 can sustain extended periods of use without compromising performance, making it ideal for lengthy performances or all-day events.

The Linear AE-100 also boasts a sleek and modern design, featuring a user-friendly interface with clearly labeled controls for ease of operation. Its build quality reflects durability, designed to withstand the rigors of both touring and fixed installations.

In summary, the Linear AE-100 is a powerful and efficient amplifier packed with features that cater to the needs of audio professionals and enthusiasts. With its robust power output, advanced protection mechanisms, versatile connectivity options, and intelligent cooling system, it stands out as a reliable choice for anyone seeking high-quality audio performance. Whether for live sound applications or home audio systems, the AE-100 delivers exceptional sound quality and reliability.