STANDARD PROGRAMMING METHOD
System Options
For most installations the factory settings for the system will be appropriate. To customize the system, enter programming mode via telephone or keypad.
Use the programming worksheet supplied to log any system option changes prior to entering it into the system.
For each of the following steps, enter the Master Password and enter
Programming Mode (if the unit is not already in that mode). Exit
Programming Mode when all programming is complete.
System Display Language
The factory default language is English. Three other languages can be | SYSTEM DISPLAY LANGUAGE | PPN 38 | |||
selected as the language for the user and programming displays. | 38#LANG# | ||||
✦ NOTE: This step cannot be performed remotely through the | |||||
| telephone. | ||||
| LANG = SYSTEM DISPLAY LANGUAGE | ||||
✦ | NOTE: The system supports one display language at a time. | ||||
1 = ENGLISH | 2 = SPANISH | ||||
1. | Press | ||||
2. | Choose a language: | 3 = FRENCH | 4 = PORTUGUESE | ||
| • | Enter 1 for English | FACTORY SETTING: ENGLISH | ||
| • | Enter 2 for Spanish | |||
| • | Enter 3 for French |
|
| |
| • | Enter 4 for Portuguese |
|
| |
| KEYPAD LOCKOUT COUNT | PPN 51 | |||
3. | Press | ||||
|
|
| |||
Keypad Lockout Count | 51#COUNT# | ||||
The system counts the number of invalid Entry Codes entered at the | |||||
keypad. If the invalid entries exceeds the lockout count number, the | COUNT = NUMBER | ||||
keypad is locked out for 90 seconds. The factory setting for the lockout | |||||
count is three. The lockout value can be from one to nine. | THAT WILL CAUSE A 90 SECOND LOCKOUT | ||||
1. | Press | FACTORY SETTING: 3 TRIES | |||
|
|
| |||
2. | Enter the number for the lockout count |
|
| ||
|
| ||||
ACCESS RELAY ACTIVATION TIME | PPN 52 | ||||
3. | Press | ||||
|
|
| |||
Access Relay Activation Time | 52#SECONDS# | ||||
The factory setting will cause the access relay to activate for 4 seconds. | |||||
The activation time can be set from |
|
| |||
different types of access control devices. | SECONDS = ACTIVATION TIME | ||||
1. | Press | ||||
|
| ||||
2. | Enter the time (in seconds) for access relay to stay activated | FACTORY SETTING: 4 SECONDS | |||
3. | Press | ||||
|
|
9