PUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommendation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP-Rec-01 Rev C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP RECOMMENDATION FOR

 

 

 

 

 

 

 

 

 

 

ARMOR 151-200 WATER HEATER

 

 

 

 

 

Pump Specifications

 

 

 

 

 

 

 

 

 

 

 

Part No.

 

HorsePower

 

Flanges

 

Valute Material

Flange Material

Vendor

 

Vendor Product Series

 

Orientation

 

PUM3010

 

1/6

 

1-1/4"

 

 

Bronze

Bronze

Armstrong

 

E Series

 

Vertical

 

 

 

Installation Specifications

 

 

 

 

 

 

 

 

 

 

Recommended for

 

 

 

 

 

Based on

 

 

 

 

 

 

Pump

Model Numbers

 

 

 

Minimum GPM
Installation Type

 

 

 

 

 

 

 

Armor Wtr Htr, AW(N,L) 151-200

 

16 GPM (151) & 21 GPM (200)

Single Water Heater piped to Single Storage Tank

 

 

PUM3010

Based on

 

 

 

Based on

 

 

 

 

 

 

 

 

 

 

Minimum Pipe Diameter

 

Connecting piping

 

 

 

 

 

 

 

 

 

1-1/4"

 

 

 

Maximum 45 feet straight pipe with 4-Elbows, 2-Unions and 2-Ball Valves

 

 

IMPORTANT: Read the Armor 151-801 Installation and Operation Manual. If the planned system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.