Lochinvar 151-200 ARMOR 501-601WATER HEATER, Pump Recommendation For, Pump Specifications

Models: 151-200

1 5
Download 5 pages 35.61 Kb
Page 4
Image 4
ARMOR 501-601 WATER HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommendation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP-Rec-01 Rev C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP RECOMMENDATION FOR

 

 

 

 

 

 

 

 

 

 

ARMOR 501-601 WATER HEATER

 

 

 

 

 

Pump Specifications

 

 

 

 

 

 

 

 

 

 

 

Part No.

 

HorsePower

 

Flanges

 

Valute Material

Flange Material

Vendor

 

Vendor Product Series

 

Orientation

 

PUM30003

 

2/5

 

2"

 

 

Bronze

Bronze

Armstrong

 

E Series

 

Vertical

 

 

 

Installation Specifications

 

 

 

 

 

 

 

 

 

 

Recommended for

 

 

 

 

 

Based on

 

 

 

 

 

 

Pump

Model Numbers

 

 

 

Minimum GPM

Installation Type

 

 

 

 

 

 

 

Armor Wtr Htr, AW(N,L) 501-601

 

53 GPM (501) & 53 GPM (601)

Single Water Heater piped to Single Storage Tank

 

 

PUM30003

Based on

 

 

 

Based on

 

 

 

 

 

 

 

 

 

 

Minimum Pipe Diameter

 

Connecting piping

 

 

 

 

 

 

 

 

 

2"

 

 

 

 

Maximum 45 feet straight pipe with 4-Elbows, 2-Unions and 2-Ball Valves

 

 

IMPORTANT: Read the Armor 151-801 Installation and Operation Manual. If the planned system exceeds the pump capacity in flow and/or head see “Pump-Curves-All Pumps” for alternate pumps and pump curves.

4

Page 4
Image 4
Lochinvar 151-200 ARMOR 501-601WATER HEATER, Pump Recommendation For, Pump Specifications, Installation Specifications