User’s Information Manual

1 Prevent combustion air contamination

￿WARNING

￿WARNING

If the boiler combustion air inlet is located in any area likely to cause contamination, or if products which would contaminate the air cannot be removed, you must have the combustion air and vent re-piped and terminated to another location. Contaminated combustion air will damage the boiler, resulting in possible severe personal injury, death, or substantial property damage.

If the boiler combustion air inlet is located in a laundry room or pool facility, for example, these areas will always contain hazardous contaminants.

Table 1A Corrosive Contaminants and Sources

Products to avoid:

Spray cans containing chloro/fluorocarbons

Permanent wave solutions

Chlorinated waxes/cleaners

Chlorine-based swimming pool chemicals

Calcium chloride used for thawing

Sodium chloride used for water softening

Refrigerant leaks

Pool and laundry products and common household and hobby products often contain fluorine or chlorine compounds. When these chemicals pass through the boiler, they can form strong acids. The acid can eat through the boiler wall, causing serious damage and presenting a possible threat of flue gas spillage or boiler water leakage into the building.

Please read the information listed in Table 1A. If contaminating chemicals will be present near the location of the boiler combustion air inlet, have your installer pipe the boiler combustion air and vent to another location, per the Knight Wall Mount Installation and Operation Manual.

Paint or varnish removers

Hydrochloric acid/muriatic acid

Cements and glues

Antistatic fabric softeners used in clothes dryers

Chlorine-type bleaches, detergents, and cleaning solvents found in household laundry rooms

Adhesives used to fasten building products and other similar products

Areas likely to have contaminants

Dry cleaning/laundry areas and establishments

￿WARNING

To prevent the potential of severe personal injury or death, check for areas and products listed in Table 1A before installing the boiler or air inlet piping.

If contaminants are found, you MUST:

Remove contaminants permanently. —OR—

Relocate air inlet and vent terminations to other areas.

Swimming pools

Metal fabrication plants

Beauty shops

Refrigeration repair shops

Photo processing plants

Auto body shops

Plastic manufacturing plants

Furniture refinishing areas and establishments

New building construction

Remodeling areas

Garages with workshops

4

Page 4
Image 4
Lochinvar 51 - 211 manual Prevent combustion air contamination, Products to avoid, Areas likely to have contaminants

51 - 211 specifications

Lochinvar 51-211 is a notable model in the realm of high-performance heating solutions, designed to efficiently meet commercial and residential hot water demands. This innovative water heater stands out due to its capacity, advanced technologies, and energy efficiency, making it a preferred choice for many.

One of the primary features of the Lochinvar 51-211 is its impressive output. With a 211,000 BTU input and a robust design, it is capable of delivering a substantial amount of hot water quickly, which is essential in applications where hot water demand fluctuates significantly. This unit is particularly suitable for large residential homes, restaurants, and other commercial settings where high-volume hot water is critical.

The Lochinvar 51-211 incorporates cutting-edge technology to optimize its performance. It features a stainless steel heat exchanger that not only enhances durability but also improves heat transfer efficiency. This construction provides not only longevity but also minimizes maintenance needs over the lifespan of the unit. Additionally, its smart control system allows for precise temperature control and monitoring, ensuring that users can easily customize settings according to their needs.

Energy efficiency is a cornerstone of the Lochinvar brand, and the 51-211 model is no exception. It achieves a high Energy Factor (EF), which translates to lower energy costs and reduced environmental impact. This unit is also designed to meet stringent efficiency standards, making it an ideal option for environmentally conscious consumers.

Another characteristic of the Lochinvar 51-211 is its versatility in installation. It can be installed in various configurations, allowing for flexible integration into existing systems. Furthermore, its compact design means it can fit into tight spaces without compromising functionality, making it perfect for urban settings where space is often a premium.

Safety features are also a priority in the design of the Lochinvar 51-211. The unit incorporates built-in safeguards, including flue gas monitoring and a vent system designed to prevent backdrafts, ensuring reliable and safe operation for users.

In summary, the Lochinvar 51-211 water heater combines high BTU output, advanced stainless steel technology, excellent energy efficiency, versatile installation options, and safety features. These attributes make it a top choice for anyone in need of a dependable and efficient hot water solution. With Lochinvar’s commitment to quality, users can feel confident that this unit will provide consistent performance for years to come.