ARMOR
Condensing Water Heater
Submittal Sheet
AWP-Sub-08
ARMORTM CONDENSING WATER HEATER PACKAGE SYSTEM
JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
RECOVERY RATE IN GPH_______________________________________@________°F RISE
NOTES
Standard Features
>Up to 98% Thermal Efficiency
>Modulating Burner with 5:1 Turndown
>
>Low NOx Operation
>Sealed Combustion
>Low Gas Pressure Operation
>Vertical & Horizontal
>PVC, CPVC or SS Venting up to 100 Feet
>PVC/CPVC Sidewall Vent Termination
>Stainless Steel Heat Exchanger
>All Welded Construction, Gasketless Design
>160 psi Working Pressure
>ASME Construction (AW
>Natural to L.P. Conversion Kit
>All Bronze Circulating Pump
>On/Off Switch
>Flow Switch
>ASME Temperature & Pressure Relief Valve
>Temperature & Pressure Gauge (AW
>Downstream Test Valves (AW
>Adjustable Leveling Legs
>Tank Sensor
>Adjustable High Limit w/ Manual Reset
>Automatic Reset High Limit
>Condensate Trap
>Zero Clearances to Combustible Material
>5 Year Limited Warranty (See Warranty for Details)
>1 Year Parts Warranty (See Warranty for Details)
Smart System Features
>SMART SYSTEM Digital Operating Control
>Multi Color Graphic LCD Display
>Built in Cascading Sequencer for up to 8 Water Heaters
>Lead Lag
>Efficiency Optimization
>Building Management System Integration
>Modbus Communication (Optional)
>
>
>
>Access to BMS Settings Through Graphic LCD Display
>Low Water Flow Safety Control & Indication
>Inlet & Outlet Temperature Sensors & Readout
>Flue Temperature Sensor
>Water Heater Pump Control
>Pump Delay with Freeze Protection
>Pump Exercise
>Night Setback
>Building Recirculation loop Pump Control*
>Night Setback of Building Recirculation Loop*
>Time Clock
>Maintenance Reminder
>Ability to program name and number into the product as contact
>High Voltage Terminal Strip
>120 VAC / 60 Hertz / 1 Phase Power Supply
>Pump Control Contacts
>Water Heater Pump Control Contacts
>Building Recirculation Pump Control Contacts
>Low Voltage Terminal Strip
>24 VAC Auxiliary Device Relay
>Auxiliary Proving Switch Contacts
>Flow Switch Contacts
>Alarm on Any Failure Contacts
>Runtime Contacts
>Tank Sensor Contacts
>Cascade Contacts
>
>
>Modbus Contacts
*Exclusive to Lochinvar
Optional Equipment
>Alarm Bell
>Condensate Neutralization Kit
>High & Low Gas Pressure Switches (AW
>Concentric Vent Kit
(3” & 4” PVC/CPVC only)
>ModBus Communications
>SMART SYSTEM PC Software
>Room Air Vent Kits
>Stack Frame
Firing Control Systems
> M9 Standard Construction
> M7 California Code
(AW
>M13 CSD1 / FM / GE Gap (AW