Installation & Operation Manual

4 Domestic side (tank) piping

Anti-scald valves (mixing valves)

Temperature & pressure (T&P) relief valve

Anti-scald valves used with water heaters are also called tempering valves or mixing valves. An anti-scald valve mixes cold water in with the outgoing hot water to assure that hot water reaching a building fixture is at a temperature low enough to be safe. ASSE1017 and ASSE1070 certified valves are recommended.

Usually, the maximum temperature of the outlet water will stay near the setting of the tank control. In some cases, however, hot water usage patterns can cause the outlet water temperature to rise significantly above the control setting.

The temperature of water going to the fixtures may be more carefully controlled through the use of a thermostatic mixing valve. This device blends a controlled amount of cold water with the hot water leaving the tank so that water at a more constant temperature exits the mixing valve. Anti-scald mixing valve piping is illustrated in FIG.’s 3-1 thru 3-4.

￿WARNING An anti-scald mixing valve does not eliminate the risk of scalding.

*Set the tank thermostat as low as practical.

*Feel water before bathing or showering.

*If anti-scald or anti-chill protection is required, use devices specifically designed for such service. Install these devices in accordance with their manufacturer’s instructions.

￿WARNING

For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes. This equipment shall not be less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 and the Standard CAN1-4.4, Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves. The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater. The combination temperature and pressure relief valve shall also have an hourly rated temperature steam BTU discharge capacity not less than shown in Table 4A.

Install the combination temperature and pressure relief valve into the opening provided and marked for this purpose on the water heater.

Install drain valve

Drain valve and fittings are supplied by others.

Standard Installation

Install a tee connection at the domestic cold water inlet (FIG. 4-1).

Figure 4-1Drain Valve Installed

DRAIN

VALVE

12

Page 12
Image 12
Lochinvar SIT119, SIT030 operation manual Install drain valve, Standard Installation

SIT030, SIT119 specifications

Lochinvar is a renowned manufacturer of high-efficiency heating solutions, including a range of commercial and residential boilers. Among their offerings are the Lochinvar SIT119 and SIT030 models, which exemplify the brand's commitment to innovation and efficiency in modern heating systems.

The Lochinvar SIT119 is designed for medium to large residential applications, boasting a powerful heating capacity. This model features a robust stainless steel heat exchanger that not only enhances durability but also promotes optimal heat transfer. As part of Lochinvar’s commitment to energy efficiency, the SIT119 incorporates advanced features such as a modulating burner system that adjusts the flame output based on the heating demand, resulting in lower energy consumption and reduced operational costs.

In addition to its efficiency, the SIT119 is equipped with user-friendly controls that allow homeowners and technicians to easily manage and monitor the system. Its intuitive digital display provides real-time information on system performance and diagnostic capabilities, facilitating maintenance and troubleshooting. Furthermore, the SIT119’s compact design enables versatile installation options, making it suitable for various residential spaces.

On the other hand, the Lochinvar SIT030 is tailored for smaller residential applications. Despite its smaller size, it doesn’t compromise on performance or efficiency. This model also features a high-quality stainless steel heat exchanger, ensuring longevity and consistent heating performance. Like the SIT119, the SIT030 utilizes a modulating burner system to optimize energy use, making it an environmentally friendly choice for homeowners seeking effective heating solutions.

One notable characteristic of the SIT030 is its low NOx emission design, which aligns with contemporary environmental standards and helps reduce the carbon footprint associated with heating. Additionally, both models support easy integration with existing heating systems and can be paired with renewable energy sources, such as solar thermal systems, maximizing their efficiency and sustainability.

In summary, the Lochinvar SIT119 and SIT030 models stand out in the heating market, combining advanced technologies with high efficiency and user-friendly features. Their stainless steel construction, modulating burners, compact design, and emissions compliance make them excellent choices for homeowners looking to invest in reliable and eco-conscious heating solutions. With these models, Lochinvar continues to lead in producing innovative products that meet the evolving demands of the heating industry.