INSTALLATION AND SERVICE MANUAL

SSB-i&s--01

INSTALLATION AND SERVICE MANUAL

SPACE SAVER BOOSTER

ELECTRICAL INSTALLATION

 

PLUMBING INSTALLATION

INSTRUCTIONS

 

INSTRUCTIONS

 

 

 

Electric booster water heaters are available for operation on standard power systems. Check the nameplate for the proper power supply.

All internal electrical connections have been made at the factory. See Circuit Breaker and Fuse Sizing Chart for supply wire size, fuse, breaker and conduit recommendations.

WARNING !!

For proper electrical installation conforming to local electrical codes, consult a licensed electrical contractor.

WARNING !!

The main power circuit must be disconnected prior to performing any maintenance on the booster heater to avoid possible personal injury or damage to the heater.

ELECTRICAL CONNECTIONS

AL CONNECTIONS

1.Locate the heater terminal or fuse block(s) in the control box. The control box is under the front hinged jacket cover.

2.Bring power leads from a properly sized fused disconnect switch or circuit breaker through knock-out provided in base and connect to the terminal or fuse block(s). USE COPPER WIRE ONLY.

3.A grounding lug is provided near the supply terminals. An equipment grounding conductor must be properly connected to it.

4.Replace and secure cover(s).

CAUTION !!

Do not turn on power to booster heater until the tank has been filled with water and all air has been vented through the dishwater rinse nozzle. The heating elements will burn out in seconds if operated when they are not immersed in water, unless the heater is equipped with a low-water cutoff (LWCO).

For the most effective operation install the booster heater as close as possible to the dishwasher.

NOTE:

Employ recirculation if distance between booster and dishwasher exceeds NSF specifications.

WARNING !!

To assure proper operation and avoid a possible unsafe condition, the booster heater must be installed in a horizontal position with the base parallel to the floor and the inlet connection at the lowest point.

TEMPERATURE AND PRESSURE RELIEF VALVE

For protection against excessive pressures and temperatures in the booster heater, install temperature and pressure protective equipment required by local codes. The manufacturer supplies valves constructed with brass working parts and heat resistant silicone seat discs for all booster heater models.

WARNING !!

Valves supplied by manufacturer are designed for high temperature commercial operation. Do not substitute OEM valves with valves designed for domestic water heaters.

Temperature/pressure protective equipment should not be less than a

combination temperature/pressure relief valve certified by a nationally

recognized testing laboratory that maintains periodic inspection of the

production of this equipment and meets the requirements for Relief

Valves and Automatic Shutoff Devices for Hot Water Supply Systems,

ANSI Z21.22-latest edition. The temperature/pressure relief valve

must be marked with a minimum set pressure not to exceed the marked

hydrostatic test pressure of the booster heater.