Lopi ULC S627-93, CSA B366.2 Installation Information, Testing, De Af Gd, E Ce, Fe Af De Ce Dg

Models: ASTM E 1509-95 CSA B366.2 UL 1482-94 ULC S627-93

1 12
Download 12 pages 25.69 Kb
Page 4
Image 4
INSTALLATION INFORMATION

INSTALLATION INFORMATION

FREESTANDING CLEARANCES TO

UNPROTECTED COMBUSTIBLE WALLS

Stove clearances measured from stove top. Connector clearances measured from the flue pipe.

INSERT CLEARANCES TO

UNPROTECTED COMBUSTIBLES

Mantle: combustible

or non-combustible

A

B

C

DE DE  AFEFE  AF AF

GD

TESTINGManual backgroundManual backgroundManual backgroundC

B

B

 

C

J

A

 

 

 

 

 

G

 

F

 

 

 

D

H

I

K

 

 

 

 

E

 

 

 

Minimum Clearances To Combustibles:

 

E

CE

FE Manual backgroundManual background AF

Manual backgroundManual background DE

CE DG Manual backgroundManual background

Pioneer Bay

Yankee Bay

A - Min. 32”

A - Min. 32 3/4”

(10” from hopper lid)

(6 1/4” from hopper lid)

B - Min. 35”

B - Min. 33” to 38”

(13” from hopper lid)

Depending on mantle depth

C - Min. 34 1/8”

See Owner’s Manual for details

C - Min. 42”

(6” from hopper lid)

(7” from hopper lid)

 

D - Min. 15 1/2”*

D - Min. 18”*

(6” from door opening)

(6” from door opening)

 

E - Min. 34 1/8”*

E - Min. 36”*

(6” from door opening)

(6” from door opening)

Minimum Clearances To Combustibles:

 

 

Pioneer

Yankee

Unit To Backwall

A - Min. 3”

A - Min. 3”

Unit To Sidewall

B - Min. 9”

B - Min. 9”

Front Hearth

 

 

Extension

C - Min. 6”

C - Min. 6”

Connector Tee

 

 

to Rear of Hearth

D - Min. 2”

D - Min. 2”

Corner of Unit

 

 

To Wall

E - Min. 2”

E - Min. 3”

Connector Tee

 

 

to Wall

F - Min. 3”

F - Min. 3”

Hearth Pad*

G - Min. 21 5/8” Wide

G - Min. 25” Wide

 

x 26 7/8” Deep

x 29” Deep

*The pellet stove must be installed on a non-combustible floor protector which is a minimum .018” thick - 26 gauge.

ALCOVE REQUIREMENTS

 

 

Pioneer

Yankee

Minimum Height

60”

60”

Maximum Depth

48”

48”

Minimum Width

42”

43”

F - 9”

F - 8 3/4”

(to side combustible)

(to side combustible)

*The pellet insert must be installed on a non-combustible floor protector which is a minimum .018” thick - 26 gauge.

Fireplace Minimum Dimensions:

G - 19 5/8”

G - 20” to 25 3/4” depending on hopper

H - 30”

height - See Owner’s Manual for details

H - 36”

(includes circuit board)

 

(includes circuit board)

I - 16 5/8”

I - 14”

(includes 5” for vent)

(includes 5” for vent)

 

Installation:

J - The vent should be routed to the fireplace prior to installing the insert. See Owner’s Manual for details on vent location.

K - The insert must protrude 9 3/8” (Pioneer Bay) 12” (Yankee Bay) onto the hearth for the panels to fit correctly.

Surround Panels:

 

Pioneer Bay

Yankee Bay

Rectangular Panels:

Rectangular Panels:

8" x 10" Panels

8" x 10" Panels

28 7/8"H x 40 1/2"W

32"H x 45"W

10" x 13" Panels

 

31 7/8"H x 44 1/2"W

 

TESTING

Pioneer and Pioneer Bay safety tested and certified by Warnock Hersey. Yankee and Yankee Bay safety tested and certified by Omni-Test Laboratories. All models tested to UL 1482-94/ULC S627-93/CSA B366.2/ASTM E 1509-95.

These pellet fired appliances have been tested and listed for use in manufactured homes in accordance with Oregon Administrative Rules 814-23-900

through 814-23-909.

Page 4
Image 4
Lopi ULC S627-93, ASTM E 1509-95, CSA B366.2, UL 1482-94 Installation Information, Testing, De Af Gd, E Ce, Fe Af De Ce Dg