Appendix 6: RS232 Remote Protocol

The RS-232 protocol allows you to control the DXR109 from a PC or any other serial device. Data: 8 bit data, 1 start bit, 1 stop bit

ACT (0xFF)

0xCO

 

ID

FUNCTION

STOP 0X7F

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

 

CODE

ASCII

FUNCTION

 

CODE

ASCII

 

 

 

 

 

 

 

 

 

KEY_MENU

 

 

0x4D

M

KEY_CH1

 

0x31

1

KEY_SELECT

 

 

0x73

s

KEY_CH2

 

0x32

2

KEY_ENTER

 

 

0x0D

ENTER

KEY_CH3

 

0x33

3

KEY_4CUT

 

 

0x61

a

KEY_CH4

 

0x34

4

KEY_ZOOM

 

 

0x5A

Z

KEY_CH5

 

0x35

5

KEY_9CUT

 

 

0x62

b

KEY_CH6

 

0x36

6

KEY_PIP

 

 

0x70

p

KEY_CH7

 

0x37

7

KEY_16CUT

 

 

0x63

c

KEY_CH8

 

0x38

8

KEY_SLOW

 

 

0x53

S

KEY_CH9

 

0x39

9

KEY_REC

 

 

0x72

r

 

 

 

 

KEY_LEFT

 

 

0x4C

L

 

 

 

 

KEY_UP

 

 

0x55

U

 

 

 

 

KEY_PLAY

 

 

0x50

P

 

 

 

 

KEY_DOWN

 

 

0x4E

N

 

 

 

 

KEY_RIGHT

 

 

0x52

R

 

 

 

 

KEY_POWER

 

 

0x57

W

 

 

 

 

KEY_KEY_LOCK

 

 

0x4B

K

 

 

 

 

32