Louisville Tin and Stove 78111 Contents, Introduction, Counterflow Wall Furnace Specifications

Models: 78111

1 27
Download 27 pages 27.08 Kb
Page 2
Image 2
CONTENTS

The State of Massachusetts requires that installation and service of a gas appliance be performed by a plumber or gas fitter licensed in the Commonwealth of Massachusetts.

CONTENTS

Contents……………………………………………........... 2

Lighting & Re-Lighting Instructions……………….. 10,11

Introduction…………………………………………. 2

Operation………………………………………….....….

12

Specifications………………………………………..

2

Terminal Block Wiring Diagram……………….....…… 13

Safety Rules…………………………………………

3

ManualReset…………………………………....……..

13

Helpful Installation Information……………….........….

3

Maintenance Instructions…………………….………

13

Connecting theVent……………………………....…..… 3,4

WiringDiagram……………………………….....……..14,15

Combustion and VentilationAir

5

Side & Rear Discharge Kits……………………...……16,17

FurnaceLocation………………………………….....….

6

Trouble Shooting Chart…………………………..….. 18,19

Rough-In Instructions…………………………..…..…. 6,7

Repair Parts (break down)………………………..….. 20-24

Installation……………………………………….......…..

8

RepairPartsList…………………………………....….21-25

Controls…………………………………………........…..

9

Warranty………………………………………….....….

27

Pilot Flame Adjustment…………………………......…..

9

 

 

INTRODUCTION

THIS ISAGAS-FIRED, GRAVITYVENTED WALL FURNACE THAT WILLOPERATE SAFELYAND PROVIDEAN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATEDAND MAINTAINEDAS RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLYBEFORE INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICEAGENCIES,THE GAS SUPPLIER, ORTHE MANUFACTURER.

COUNTERFLOW WALL FURNACE SPECIFICATIONS

Your counterflow wall furnace is packed in a single carton that also includes thermostat, thermostat wire, and insulated staples. The thermostat, wire, and staples are packed in the burner compartment and are accessible by removing the burner access door. While the burner access door is open, check the rating plate to verify that the model number is correct and that the wall furnace is equipped for the type gas you intend to use.

 

 

 

Vent

 

 

 

 

 

Approx.

Model Type

Type

BTU/HR.

Size

Gas

 

Blower

 

 

Shipping

Number Control

Gas

Input

(Oval)

Inlet

Finished Dimensions

Speed

Amps

CFM

Weight

 

MODELS WITH LOW-BTU STANDING PILOT

 

 

CF353C-H 24Volt Nat.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H

1

1.95

320

95 Lbs.

CF354C-H 24Volt L.P.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H

1

1.95

320

95 Lbs.

CF503C-H 24Volt Nat.

50,000

4”

½” 14-5/16”Wx10¼”Dx81-5/16”H

2

2.25

440

104 Lbs.

CF504C-H 24Volt L.P.

50,000

4”

½” 14-5/16”Wx10¼”Dx81-5/16”H

2

2.25

440

104 Lbs.

CF653C-H 24Volt Nat.

65,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H

2

2.25

440

107 Lbs.

CF654C-H 24Volt L.P.

65,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H

2

2.25

440

107 lbs.

 

 

 

 

 

 

 

MODELS WITH INTERMITTENT IGNITION

 

 

CF357C-H 24 Volt Nat.

35,000

4”

½”

14-5/16”Wx10¼”Dx78-5/8” H

1

2.2

320

95 Lbs.

CF358C-H 24 Volt L.P.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H

1

2.25

320

95 Lbs.

CF557C-H 24 Volt Nat.

55,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H

2

2.5

440

107 Lbs.

CF558C-H 24 Volt L.P.

55,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H

2

2.55

440

107 Lbs.

 

 

 

 

 

 

 

 

 

 