TSK WALL STAT KIT OPTIONAL
WALL THERMOSTAT INSTALLATION INSTRUCTIONS
Your heater can be
NOTE: Do not disconnect the wire from the blocked flue switch to the “TH” terminal on the gas valve.
STEP 1. Disconnect wire leading from Part #70080 (Bulb Control Switch) from valve.
STEP 2. Cut the remaining wire leading from Part #70080 (Bulb Control Switch) to the blocked flue switch, leaving its end connected to the blocked flue switch and leaving enough length to reach the gas valve. Strip 1/2” of the insulation from the cut end of the wire.
STEP 3. Connect one leg of thermostat wire to the “TH/PP” terminal on the gas valve.
STEP 4. Connect second leg from the thermostat to the stripped wire coming from the blocked flue switch. Secure this connection inside the heater cabinet.
STEP 5. Secure both red wires from blocked flue switch inside heater cabinet. Make sure none of the wires have enough slack to lay against the heat exchanger or draft hood.
THERMOSTAT
OPTIONAL
BLOCKED
FLUE SWITCH
PILOT
GENERATOR
WIRE
NUT
(Not provided)
Page 14