cable in the event a short occurs.
Crimp
connectors are supplied to
attach the fuse holder to the
power cable. The red wire in the
power cable is the
positive con-
ductor The black wire is the
ground or negative conductor.
The graph is protected from
accidental polarity reversals and
no damage will occur if the wires
are reversed. The unit will not
operate until the proper polarity
is
applied.
FIGURE 3
When installing the power
cable,
you will find two extra wires com-
ing from the power
cable. The
green one is for an optional Power
Booster and the other
white wire
is for connection to a Loran C
receiver If neither of these fea-
tures are going
to be used, tape
the ends of the
green
and white
wires so that
they
cannot short
Refer to the Advanced Operation
section for more information on
these wires.
TRANSDUCER SELECTION
Lowrance offers you the choice
of transducers with either an 8 or
20 degree cone
angle that will
interchange with any of our 192
kHz sonar units. In other
words,
any Lowrance sonar instrument
can be used with any Lowrance
transducer of the same frequency
without retuning of any kind, and
no loss of performance. However,
the use of any other manufac-
turer's transducer will result in a
loss of performance.
Now you can select the trans-
ducer design and cone angle
to
best fit your specific needs. Gen-
erally, wide cone
angle transdu-
cers
(20 degrees) are ideally
suited for operating in shallow
water or at medium depths. The
20 degree cone
angle
allows
you
to see more of the underwater
world. In 15 feet of water the 20
degree cone covers an area of the
bottom thath about 6 feet across.
The 8 degree transducer covers
only about a 2 foot circle.
way
to slow the chart paper The
chart below gives the range

of

the
Paper Save function and the
amount that each level slows the
paper.
To enable the Paper Save
function, simply press the level of
paper
save desired, then 2nd,
then 6. The paper should slow
immediately. For example,
suppose you wish to slow the
paper
down to 1/4 its present
speed. Press 3 - 2nd - 6 and the
paper
will now be traveling four
times slower than its previous
speed.
When the Paper Save function
is enabled, the X-16 will print
PSV= and the level of paper save
that you selected. For example, in
our previous example the Paper
Save value was 3. The X-1 6 will
print PSV=3 on the bottom line of
the chart paper (See Figure 45.)
- -- 1
Lao
34.0 - - -
360
48,0
60.OFT— rL LOUPAITCE PSU3
Figure 45
The Paper Save function can
also be used with the Alternate
Transmit and Print function which
will cut any Paper Save speed in
half. This gives fourteen different
paper speeds selectable by the
operator.
To disable the Paper Save
function, simply press 0 - 2nd - 6,
and the paper will speed up.
PRINT INTENSITY
Three levels of print intensity are
provided for different conditions.
The stylus printing can be
adjusted to print lighter or darker
by using the Print Intensity mode.
When the X-16 leaves the factory,
the Print Intensity is set to level 1.
To change this setting, press the
level of intensity desired, from 0 to
2 (0 is lightest, 2 is darkest) and
then press 2nd - LINES.
For example, if the stylus is
printing too light, press 2 - 2nd -
LINES and the markings on the
chart paper should become
darker
This feature is useful when a
stylus becomes old. By using the
'2" level or darkest level, the
printing can improve. If, when
using very
slow paper speeds, the
record has much overprint due to
multiple stylus strikes in a small
area, the '0" or lightest level can
PAPER SAVE
LEVEL CHART SPEED REDUCED TO
1 1/2
2 1/
3 1/4
4 1/5
5 1/6
6 1/
7 1/
FIGURE 4
Co,e
AnSI. I
O.pth
L. 7ft lIlt I
II" 4 I
III' 11 13
1240 28 7' I
50'
100'
150'
200'
8°at3db
4 25
PDF compression, OCR, web-optimization with CVISION's PdfCompressor