3.2Physical and Environmental Specifications

The design and implementation of the Serial ATA storage adapters minimizes electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The board carries the CE mark, C-Tick mark, FCC Self-Certification logo, Canadian Compliance Statement, Korean MIC, Taiwan BSMI, and Japan VCCI, and it meets the requirements of CISPR Class B.

3.2.1Electrical Characteristics

Table 3.5 lists the maximum power requirements for the MegaRAID SATA 150 storage adapters under normal operation.

Table 3.5

Maximum Power Requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Over the Operating

Host Adapter

PCI/PCI-X +5.0 V

PCI/PCI-X +3.3 V

Power

Range

 

 

 

 

 

 

 

SATA 150-61

 

0.85 A

1.29 A

 

 

 

(load sharing enabled)

 

 

 

0

°C to 40 °C with BBU

 

 

 

 

11 W

0

°C to 45 °C without

SATA 150-61

 

1.63 A

0 A

 

 

BBU

(load sharing disabled)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SATA 150-4

 

1.5 A

0 A

7.6 W

0

°C to 45 °C

 

 

 

 

 

 

 

SATA 150-2

 

0.35 A

N/A

1.77 W

0

°C to 45 °C

 

 

 

 

 

 

 

1.The total power for the SATA 150-6 takes into consideration the charging of the BBU from the +12 V and the on-board regulator efficiencies.

3.2.2Thermal and Atmospheric Characteristics

The atmospheric characteristics for the MegaRAID SATA 150 storage adapters are:

Temperature range: 0 °C to 40 °C with BBU; 0 °C to 45 °C without BBU (dry bulb)

Relative humidity range: 20% to 80% noncondensing

Maximum dew point temperature: 32 °C

3-8

SATA 150 Storage Adapter Characteristics

Copyright © 2002–2006 by LSI Logic Corporation. All rights reserved.