This is a guide to the information needed to install a DEFINITY ONE Communications
System. For expanded information about these topics, see
DEFINITY ONE
Communications System Release 2.0 Installation and Upgrades
(555-233-109).
1. Install and cable the cabinet (same as ProLogix).
2. Power up the system (same as ProLogix).
3. Connect the laptop computer.
4. Access DEFINITY ONE via telnet and start a LAC bash session.
5. Verify the serial number (use

serialnumber

command). Ensure that the
serial number matches the number on the TN795 faceplate.
6. Acquire a license file. License file information is available online. For
further information, contact your Lucent technical services
representative.
For external access: www. lucent-teamworks.com
For internal access: http://info.dr.lucent.com/~epr/contry
7. Request the RAS IP address from the INADS contact person.
8. Run

setip

to set the RAS IP address, the system name; and, if
applicable, the customer LAN information.
9. Reboot the system, using the

reboot nice

command.
10. Wait for notification from INADS that the license file has been installed.
This requires a reboot.
11. Administer the DEFINITY ONE platform. For example, set the system
time and time zone, and enable customer logins. To enable AUDIX
customer logins, execute the following commands from a Bash sh ell:
net user sa <new password>
net user sa /active
(Repeat these commands for vm and browse logins.)
12. Administer applications (DEFINITY, AUDIX, and AUDIX Networking).
Typical Bash (GAS) commands for installation

Command Description

alarmorig Turns on alarm origination from the GAM (INADS)
alarmstat Gives global alarm status (major, minor, or none) for GAM ,
DEFINITY, and AUDIX
cleargamalarm Clears alarms after analysis
d1stat Displays the status of all application groups running on the
system
environment Displays the TN795 temperature and voltage ranges
ftpserv Enables the ftp service
gamalarmstat Displays GAM alarm information
installconfig Installs license files (INADS)
lucent help Lists all commands
oss Sets telephone numbers for outgoing INADS calls
pcAnywhere Starts the pcAnywhere application (use -c to stop applica-
tion)
reboot Reboots system as follows:
nice: shuts down applications and Windows NT in a
graceful manner
immediate: reboots the system without waiting for the
applications to shut down, causing possible loss of voice
messages that are being recorded and all calls drop
restartcause Displays the restart causes for system (for technician/
TSC)
setip Sets the IP address, subnet mask, and default gateway of
the LAN interface to the customer’s LAN. Turns on RAS.
Reboot is required.
shutdown Shuts down:
all: Lucent DEFINITY ONE applications
system: all Lucent DEFINITY ONE applications and Win-
dows NT
appname: the name of the application to be shut down
camp-on: (AUDIX feature) notifies users of a system shut-
down all and waits for users to end their sessions before
shutting down
serialnumber Reads and displays the serial number of the circuit pack