11
#8Installingthroughtheceilingvent
Throughtheceilingvent,followPLvent
manufacturersrecommendationswhenusingwall
andceilingpassthrough.
Fig.14
Noinsulationor
othercombustible
materialsare
allowedwithin3"
ofthePLventpipe.
PLventmanufacturer's
firestopspacerandsupport
(SeePage9for
corner
installation
clearances)
Minimumflueventconfiguration
Itisrecommendedthat
outsideairbeinstalledwiththis
ventingconfiguration.
Min.abovegroundlevel

18"

Stormcollar
Flashing
3"min. 3"min.
12"min.
3"min.
Fig.15
Fig.16
Venting
DONOTINSTALLAFLUEDAMPERINTHE
EXHAUSTVENTINGSYSTEMOFTHISUNIT.
DONOTCONNECTTHISUNITTOACHIMNEY
FLUESERVINGANOTHERAPPLIANCE.
INSTALLVENTATCLEARANCESSPECIFIED
BYTHEMANUFACTURER
CAUTION
DONOTINSTALLINSLEEPINGROOM
WARNINGCAUTION
THESTRUCTURALINTEGRITYOFTHE
MOBILEHOMEFLOOR,WALL,ANDCEILING/
ROOFMUSTBEMAINTAINED.
THESTOVEISHOTWHILEINOPERATION.
KEEPCHILDREN,CLOTHINGAND
FURNITUREAWAY.CONTACTMAYCAUSE
SKINBURNS.