11
#8InstallingthroughtheceilingventThroughtheceilingvent,followPLvent
manufacturersrecommendationswhenusingwall
andceilingpassthrough.
Fig.14
Noinsulationor
othercombustible
materialsare
allowedwithin3"
ofthePLventpipe.
PLventmanufacturer's
firestopspacerandsupport
(SeePage9for
corner
installation
clearances)
MinimumflueventconfigurationItisrecommendedthat
outsideairbeinstalledwiththis
ventingconfiguration.
Min.abovegroundlevel
18"
Stormcollar
Flashing
3"min. 3"min.
12"min.
3"min.
Fig.15
Fig.16
Venting
DONOTINSTALLAFLUEDAMPERINTHE
EXHAUSTVENTINGSYSTEMOFTHISUNIT.
DONOTCONNECTTHISUNITTOACHIMNEY
FLUESERVINGANOTHERAPPLIANCE.
INSTALLVENTATCLEARANCESSPECIFIED
BYTHEMANUFACTURER
CAUTIONDONOTINSTALLINSLEEPINGROOM
WARNINGCAUTIONTHESTRUCTURALINTEGRITYOFTHE
MOBILEHOMEFLOOR,WALL,ANDCEILING/
ROOFMUSTBEMAINTAINED.
THESTOVEISHOTWHILEINOPERATION.
KEEPCHILDREN,CLOTHINGAND
FURNITUREAWAY.CONTACTMAYCAUSE
SKINBURNS.