INSTALLATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS FOR

ELV1/PSPLV510

Programmable Line Voltage Thermostat

LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA 43331-04

WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.

Energizer® is a registered trademark of Eveready Battery Company, Inc.

DURACELL® is a registered trademark of The Gillette Company, Inc.

INSTALLATION

W A R N I N G

This Thermostat is a line voltage (120 / 240 Vac) control. Do not install it unless you are completely familiar with house wiring. If improperly handled, there can be a risk of electric shock hazard which may cause serious injury or death.

The thermostat is rated for normal full load current on a dual residential 20A circuit breaker or fuse block. Do not use on circuits protected by higher-rated over-current protection devices. Some sustained fault conditions can cause product failure.

Do NOT connect to voltage different from the device rating.

C A U T I O N

Disconnect power supply before making wire connections to prevent electrical shock or equipment damage.

All wiring must comply with applicable codes and ordinances.

Thermostats are designed to be used with appliances having a limit control.

Maximum load for this thermostat MUST NOT EXCEED 3800W, otherwise a potential fire hazard exists.

Location:

Install a vertical switch box for mounting the thermostat approximately 1.5 m (5 ft.) above the floor on an inside wall where the thermostat will be exposed to average room temperature. The thermostat must be placed away from concealed warm or cold water pipes, air ducts, or drafts from hallways, fireplaces or stairways to sense temperature properly. Do not place the thermostat above the heater.

WIRING

For Use On:

Heating Only 120/240 Vac Single Pole Applications

Baseboard, Ceiling Cable and other Radiant Heat

Not For Use On:

Double Pole Applications

Heating/Cooling or Cooling Only

Low Voltage (24Vac) Systems

Electrical Rating

16A at 120/240 Vac

1900W at 120Vac (Non-Inductive) 3800W at 240 Vac (Non-Inductive)

Temperature Differential

• ±1°F Factory Preset; Adjustable

Batteries

Two Energizer® or DURACELL® “AA” alkaline batteries

(not included)

Programming

Preprogrammed - 4 Periods per day

5 / 2 Programming

Weekdays/Weekends can be different

°F / °C Changeable

Temporary Temperature Override

Vacation Hold

Dimensions

4.7” T x 2.7” W x 2.4” D

1.4” D from wall surface

Wall Plate

4.8” W x 5.0” H Wallplate Included

1.Disconnect power while installing. Double check that the thermostat is rated for the voltage and amperage load to be controlled.

2.Remove the cover by carefully pressing the button at the bottom of the thermostat and swinging the body up and away.

3.When replacing an old line voltage wall thermostat, remove it carefully to avoid damage to the insulation on the wiring. Check the old insulation for cracks, nicks, or fraying and apply certified electrical tape where necessary to achieve adequate insulation, or replace the wires in an approved fashion.

4.Attach the wires with solderless wire connectors (provided). Be sure that all wire connectors are tight.

© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED