Pop-Up Wizard Configuration Chart

Displayed

Choice

Default

 

 

 

SCAL

F° or C°

F°

 

 

 

CLOC

12 or 24 hour

12

 

 

 

LITE

1=always on, 0=off

0

 

 

 

DIFF

Set Differential, 0.5-3 F° or 0.5-1.5 C°

1 F°

 

 

 

DIF2*

Set 2nd Stage Differential, 1-6 F° or 0.5-3 C°

2 F°

 

 

 

DLY2*

2nd stage time delay, 5-40 min

20

 

 

 

DLY3**

3rd stage time delay, 5-40 min

20

 

 

 

AUTO

Enable Auto change over, Y = Yes, N = No

Y

 

 

 

DEDB

Deadband in Degree’s, 1 – 8 F°

3 F°

 

 

 

HI

Upper heating limit, 45-90 F°

90 F°

 

 

 

LO

Lower Cooling Limit, 45-90 F°

45 F°

 

 

 

VAC HEAT***

Vacation Heating Set point, 45-90 F°

60 F°

 

 

 

VAC COOL***

Vacation Cooling Set point, 45-90 F°

85 F°

 

 

 

CHECK

Filter Monitor, hours, OFF – 9900

OFF

 

 

 

CYCL

Compressor Short Cycle Delay, minutes, 0 – 5

5

 

 

 

CAL

Temperature Calibration Offset, - 3 to 3 F°

0

 

 

 