Reference Manual D AD 3220 B Version 1.0

Switch Function Detail

All settings are stored in Flash Ram inside the module (see Auto Store section in this manual). Settings will be recalled on power up.

Dip Switch 1

This switch enables local control using the dip- switches. ON enables local control and makes selections on the dipswitch active, and OFF disables local control (locking out any local changes)

Note.

When Switch 1 is initially switched to ON, the static settings currently set on the dip-switches may not reflect the actual configuration stored in the module. This is because all settings can be changed from the remote control system or via the Service Adapter. This overrides the local dip switches regardless of Switch 1 ON/OFF setting. To ensure the module reads the local dip switch settings it is recommended to toggle Switch 1 ON- OFF-ONbefore making any local changes to the dip switches.

Dip Switch 2

This switch selects the mode of operation for the module. ON selects dual 1 into 4 mode where each individual AES input is distributed to four outputs. OFF selects 1 into 8 mode where input AES in 1 is distributed to all 8 outputs.

Dip Switch 3

This is not used

Dip Switch 4

This is not used

Page 16

Page 16
Image 16
Lynx D AD 3220 B manual Switch Function Detail, Dip Switch