TECHNICAL INFORMATION

HRS150 Block Diagram

LEFT/MONO

LINEOUTPUT

RIGHT

LINEOUTPUT

SUBWOOFER

2 1

3

2 1

3

+100V +90V +15V

 

 

 

–15V

–90V –100V

SENSE RESISTOR

POWER

AMPLIFIER

 

 

 

OUT IN

ACE-BASSEQ

INPUT

SENSITIVITY

(CW=THX)

COMPRESSOR

POWERSUPPLYTRACKING/ PEAKPOWERLIMITER

FASTATTACK/SLOWRELEASE

 

 

POLARITY

0º(THX)

180º

 

 

 

OUT

OUT

OUT

A B CTL

A B CTL

A B CTL

 

 

 

 

 

 

LFE

GAIN

dB(THX)

+10dB

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

SUBSONIC

 

 

Av = 10 dB

 

 

 

 

 

 

 

FILTER

FLAT(THX)

15Hz

 

 

 

 

 

 

 

15Hz

18dB/OCT

BUTTERWORTH LPF

 

 

 

 

 

FILTER

BYPASS

FILTERIN

 

FULLRANGE (THX)

 

 

 

 

 

FILTER

SELECT

55Hz-110Hz

110Hz

ELLIPTICAL

 

 

 

CROSSOVER FREQ

55Hz-110Hz 24dB/OCTLINKWITZ-RILEY

CENTERPOSITION(80Hz)FORTHX

CROSSOVER FREQ

 

 

 

 

 

 

110Hz 42dB/OCTELLIPTICAL

LPF (FOR AC-3/DTS)

2

3

2

3

2

3

1

 

1

 

1

 

LEFT/MONO

LINEINPUT

RIGHT

LINEINPUT

SLAVE

INPUT

MASTER

OUTPUT

1

 

2

3

+5V

POWER

 

SIGNALDETECTOR

IN OUT

INPUT

 

NOTE:WHENUSEDASASLAVE, THEMASTEROUTPUTOFTHEFIRST SUBDRIVESTHISINPUT.

"POLARITY"AND"INPUTSENSITIVITY" ONLYAREACTIVEONTHISINPUT.

SUBWOOFER

BYPASS

REMOTE

INDICATOR

CLOSEDWHENSUBWOOFERISMUTED

MAXIMUMVOLTAGEALLOWEDACROSS OPENCONTACTS=24V

MAXIMUMCURRENTALLOWEDTHROUGH CLOSEDSWITCH=1A

THEPOTENTIALONTHESETERMINALSMUSTBE FLOATINGORREFERENCEDTOSAFETYGROUND

FUSE

BYPASSED

SUB

WHENSIGNALISPRESENTTHEOUTPUTISACTIVE.

OUTPUTREMAINSACTIVEFORSEVERALMINUTESAFTER SIGNALISREMOVED.

OUTPUTISINACTIVEWHENNOSIGNALISPRESENTAND BECOMESACTIVEAFTERSIGNALRETURNS.

OUTPUTS

ANDRIGHTOUTPUTS

 

 

 

HPFFROMCROSSOVERATLEFTANDRIGHT SUBWOOFERACTIVE REMOTEINDICATORSWITCHOPEN

FULL-RANGESIGNALFROMINPUTSATLEFT SUBWOOFERMUTED REMOTEINDICATORSWITCHCLOSED

 

 

 

OPEN=

CLOSED=

 

 

 

 

 

 

SUBWOOFER

BYPASS

FOOTSWITCH

MACKIE DESIGNS HRS150 THX BLOCK DIAGRAM (#061702JW)

15