Macrom Comprehensive Guide to the Features of the Stereo Amplifier 44.07

Models: 44.05 44.07

1 44
Download 44 pages 26.73 Kb
Page 6
Image 6

FEATURES

4/3/2 CHANNEL OPERATION

The power of the 44.05/44.07 can be subdivided as follows:

a)40/65 W RMS for each of the four output channels

b)40/65 W RMS on two stereo channels and 110/150 W RMS mono

c)100/150 W RMS on two stereo channels

NO AMPERAGE LIMITATIONS

The amperage limitation circuits incorporated in traditional amplifiers may cause untimely clipping and a low transient response. The absence of such circuits ensures a low T.I.M. effect, an excellent transient response and a perfect sound quality.

INPUT MODE SELECTOR

This selector allows the user to choose between 2 or 4 input signals to the amplifier.

OUTPUT MODE SELECTOR

This selector allows the user to specify the number and the configuration of the outputs.

BY-PASS OUTPUT

In the "2 CH INPUT" configuration a preamplified BY-PASS output with unitary gain can be used.

ADJUSTMENT OF INDEPENDENT CROSSOVER FREQUENCIES

This control allows for independent and continuous adjustment of the Low Pass and High Pass crossover frequencies from 50 to 160 Hz adding great versatility to your unit.

REMOTE ON/OFF

On switching the head unit on or off, the amplifier is automatically switched on or off.

RCA INPUT SENSITIVITY

The sensitivity adjustment of this new amplifier is positioned at 500 mV for optimum coupling with other MACROM sources. However, the continuous adjustment from 100 mV to 2 V is possible for easy coupling of other sources available on the market.

CHECK CONTROL INDICATOR

This LED Shows the current state of the amplifier. WHITE The unit is off.

GREEN The unit works perfectly well.

RED The unit is in the protection mode, verify connections.

TRIPLE PROTECTION

Your unit is provided with three different protection devices, as befits all high-end products: SOFT START: the amp powers gradually in order to avoid damage to the speakers in case the head unit is switched on with the volume control set to maximum.

OVERHEATING: in case of wrong installation the unit enters the protection mode before being damaged. As soon as the temperature returns to normal values, the unit resumes normal operation.

OUTPUT SHORT CIRCUIT: in case of a short circuit at the speaker outlets the unit enters the protection mode in order to avoid serious damage to the end-stage transistors. Normal operation is resumed on eliminating the short circuit.

FINAL STAGE WITH DISCREET COMPONENTS (TRANSISTORS)

8

Page 6
Image 6
Macrom 44.07, 44.05 owner manual Features

44.05, 44.07 specifications

Macrom 44.07 and 44.05 represent significant advancements in the field of software technology, specifically designed to bolster enterprise operations and enhance overall productivity. These platforms focus on streamlining workflows and improving business processes. They have been developed with an emphasis on modularity, flexibility, and integration, catering to a wide array of industry needs.

One of the main features of Macrom 44.07 and 44.05 is their robust user interface, which is both intuitive and user-friendly. This ensures that individuals at all levels of technology proficiency can easily navigate the software. The user interface has been optimized for rapid access to essential functions, making it easier for users to perform tasks efficiently. The design philosophy behind these versions also emphasizes clarity and ease of use, allowing companies to train their employees with minimal downtime.

Another notable characteristic of the Macrom 44 series is its enhanced data analytics capabilities. Organizations can harness comprehensive reporting tools that provide insights into various metrics. These insights are vital for making informed decisions and identifying areas of improvement within the company. Furthermore, Macrom 44.07 and 44.05 feature advanced predictive analytics, enabling businesses to forecast trends and make proactive adjustments to their strategies.

Integration is a key technology that sets the Macrom series apart. Macrom 44.07 and 44.05 can seamlessly connect with existing enterprise systems, such as Customer Relationship Management (CRM) and Enterprise Resource Planning (ERP) platforms. This interoperability fosters a cohesive tech ecosystem within organizations, allowing for a smooth flow of information across departments.

Additionally, these versions incorporate cloud-based solutions, promoting flexibility in how companies access and use the software. The cloud infrastructure offers scalability, ensuring that businesses can expand their software capabilities in tandem with their growth. Security features are also paramount, with robust encryption protocols in place to safeguard sensitive data against unauthorized access.

In conclusion, Macrom 44.07 and 44.05 emerge as powerful tools for modern enterprises, combining an intuitive user interface, advanced analytics, seamless integration, and cloud capabilities. These characteristics make them indispensable solutions for organizations looking to enhance their operational efficiency and drive innovation in a competitive market.