MKG SERIES GAS GRIDDLE

INSTALLATION & OPERATION

1.6.2. Gas Settings:

Orifices are sized to provide proper gas flow to the rated BTU/hr for each model. Regulator pressure must be measured and adjusted before the unit goes into service, following installation and when operational performance is in question.

Gas Type

BTU/hr(kW)

Manifold

Manifold

 

Per Burner

Pressure

Pressure

 

 

WC"

WC"

 

 

(Matchless)

(All Others)

Natural

15,000(4.4)

4.0"(10.1cm)

4.5"(11.4cm)

Propane

15,000(4.4)

10.0"(25.4cm)

10.0"(25.4cm)

FIGURE #3

2.OPERATION SECTION:

Ensure that a proper installation has been performed on the appliance and that all warnings, cautions, and notices contained in this manual have been read, understood and adhered to before proceeding.

2.1. LIGHTING INSTRUCTIONS:

2.1.1. Snap Action Thermostat Appliances:

A.Turn all thermostat knobs to the “OFF” position.

B. Open front door of the griddle, turn the manual gas shut off valve to the “ON” position.

C. Press and hold the leftmost RED pilot button, see detail Method A at right, and light the leftmost pilot with a flame source, through the left pilot hole, or depress the Piezo ignition control (If Provided). With pilot burning, keep the RED pilot knob depressed for 45 seconds or until pilot remains lit automatically.

D.Repeat steps A, B, and C for all remaining pilots.

E.Operate thermostats by turning knobs clockwise to the desired temperature and insure that burners light properly by looking through the pilot holes provided in the front panel.

NOTICE:

If appliance contains more than one pilot, the leftmost pilot MUST be lit first or the other pilot WILL NOT LIGHT.

2.1.2. Solid State and Electric Thermostat Appliances:

A.Turn all thermostat knobs to the “OFF” position, or the

lowest possible temperature setting.

B. Turn the Manual gas shut off valve to the "ON" position, this valve is located at the rear of the unit, see Figure #2.

C.Turn the RED "I/O" switch to the “I”(ON) position for

all desired Thermostats to be operated, See detail Method B at right. When the Pilot ready (Amber) light illuminates, the pilot(s) are ready to operate the main burners.

D.Repeat for all thermostat controls to be operated.

E.Operate thermostats by turning knobs clockwise to the desired temperature and insure that burners light properly by looking through the pilot holes provided in the front panel.

The RED "I/O" switch will illuminate when the thermostat calls for heat.

CAUTION

If Pilot Ready light(s) does not illuminate, Turn all Thermostat "I/O" switches for that pilot to “O”(OFF), wait five

minutes before attempting to re-light.

If Pilot(s) extinguish or gas supply is interrupted, turn thermostat knobs and the gas shut off valve to the "OFF"

position and wait 5 minutes before attempting to re-light.

6

Page 9
Image 9
Magikitch'n pmn operation manual Gas Settings, Gas Type BTU/hrkW Manifold Per Burner, Lighting Instructions