Shut Off Procedure

Step 6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valveandtransmitter. Change theswitch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmit- ter will now control the main valve, flame modu- lation level and fan control.

Step 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting. The transmitter will control the fan only.

Shut Off Procedure

Screw Cap Of Pilot

Piezo Ignitor

Adjustment

 

Local/Remote

Pilotstat

LED

Antenna

Switch

Knob

 

 

Figure 2

If the manual switch is in the REMOTE posi- tion, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter now cannot turn on the main burner or fan.

TRANSMITTER OPERATION - (refer to Figure 3 )

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

Mode

- Auto

- On

- Off

Countdown

Timer Figure 2

Fan

Figure 3

Display

-Room Temperature

-Set Temperature

-Flame Height Level

-Fan Speed Level

-Countdown Timer

-Low Battery

Flame

Up

TRANSMITTER OPERATION - (refer to Figure 3 ) (Increases Flame

Height, Fan Speed Timer, or Set Point)

Off Mode Down (Decreases Flame, Fan Speed Timer, or Set Point)

On (Manual) Mode

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and the delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.

Delay Timer Mode

The shut off delay timer has a maximum of 2 (two) hours and a minimum of 0 (zero) min- utes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 (ten) minutes.

Auto Mode

In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set tempera- ture. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set tem- perature, press the up or down key. Pushing a key once will change the temperature by 1 (one) degree. The setting temperature range from 40° F (4.5° C) to 90° F (32.0° C).

In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. "AUTO" is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button fol- lowed by the up or down key.

Pushing a key once will change the fan level by one unit. In this mode "AUTO" is displayed next to the flame icon and "MANUAL" is displayed next to the fan icon.

Change Between F/C Temperature Units

Push the up and down arrow keys simulta- neously for at least 3 seconds to toggle be- tween Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, push the time and down key simulta- neously for at least 3 seconds.

4