4 – Strobe Indications for Radio Arm/Disarm

This option allows the strobe to indicate when the system is armed and disarmed when remotely operating the system using the DSRF Series RF Receiver.

Table 60: Strobe Indications for Remote Operations

Strobe Duration

System Status

3 sec

System disarmed

6 sec

System armed in AWAY Mode

6 sec

System armed in STAY Mode 1

8 – Assign Button 4 To Operate STAY Mode 4

This option allows Button 4 on the RF3334

4 Channel Hand Held Transmitter to arm the system in STAY Mode 1.

18.2System Options 2

Location 493

Default 0

1Codepad Panic to be silent

2 Codepad Fire to be silent

4 Codepad Medical to be silent

8 Access denied (code retries) to be silent

1 – Codepad Panic To Be Silent

If this option is selected, a Codepad Panic Alarm or Radio Remote Panic Alarm does not operate the horn speaker, the bell, or the strobe outputs. If this option is not selected, all three outputs operate after a Codepad Panic Alarm is activated when a user presses [1] and [3] or [STAY] and [AWAY] at the same time on the remote codepad. Selecting this option does not affect the operation of the communication dialer.

If you want to disable reporting of a Codepad Panic Alarm, program Locations 404 and 405 as 0 (refer to Section 15.16 Codepad Panic Report on page 66).

2 – Codepad Fire To Be Silent

If this option is selected, a Codepad Fire Alarm does not operate the horn speaker, the bell, or the strobe outputs. If this option is not selected, all three outputs operate after a Codepad Fire Alarm is activated when a user presses [4] and [6] at the same time on the remote codepad. Selecting this option does not affect the operation of the communication dialer.

If you want to disable the reporting of a Codepad Fire Alarm, program Locations 407 and 408 as 0 (refer to Section 15.17 Codepad Fire Report on page 66).

4 – Codepad Medical To Be Silent

If this option is selected, a Codepad Medical Alarm does not operate the horn speaker, the bell, or the strobe outputs. If this option is not selected, all three outputs operate after a Codepad Medical Alarm is activated when a user presses [7] and [9] at the same time on the remote codepad. Selecting this option does not affect the operation of the communication dialer.

If you want to disable the reporting of a Codepad Medical Alarm, program Locations 409 and 410 as 0 (refer to Section 15.18 Codepad Medical Report on page 68).

8 – Access Denied (Code Retries) To Be Silent

If this option is selected, a Codepad Tamper Alarm does not operate the horn speaker, bell, or the strobe outputs. If this option is not selected, all three outputs operate after a Codepad Tamper Alarm occurs.

Refer to Section 15.26 System Status – Access Denied on page 69 to set the number of invalid code retries that causes an alarm condition. Selecting this option does not affect the operation of the communication dialer. If you want to disable the reporting of Access Denied reports, program Locations 424 to 426 as 0.

18.3System Options 3

Location 494

1AC fail after 1 hour (disabled – after 2 min)

2 Ignore AC fail

4 Pulse count handover allowed

8 Handover delay to be sequential

1 – AC Fail after 1 Hour

If this option is selected, the MAINS indicator flashes when the AC MAINS supply is disconnected. An AC Loss signal (Contact ID Event Code 301) is transmitted to the base station receiver after the AC MAINS supply is disconnected continuously for longer than 60 min.

If this option is not selected, the MAINS indicator flashes and an AC Loss signal (Contact ID Event Code 301) is transmitted to the base station receiver after the AC MAINS power is disconnected continuously for 2 min.

The MAINS indicator stops flashing when the AC MAINS supply is restored longer than 2 min.

An AC Loss Restore Report is transmitted to the base station receiver after the AC MAINS supply is restored continuously for more than 2 min regardless of whether this option is selected.